112717 – HIHI T-Exhaust B7 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112718 – HIHI T-Exhaust B8 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112719 – HIHI T-Exhaust B9 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112720 – HIHI T-Exhaust B10 (abs)
Red alarm. Initiated by EMU.
Cause
Individual exhaust gas
temperature of this cylinder is
too high.
112923 – MD/SD T-Exhaust
Red alarm. Initiated by EMU.
Cause
Combined alarm (for details,
refer to the source alarm).
113200 – Communication Lost ECU
Red alarm. Initiated by EMU.
Cause
No communication with ECU
CAN.
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 145).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 145).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 145).
3. Check valve drive (exhaust valves do not close).
Corrective action
1. Check emission values.
2. Check ignition timing (→ Page 145).
3. Check valve drive (exhaust valves do not close).
Corrective action
u Combined alarm (for details, refer to the source alarm).
Corrective action
1. Check supply voltage.
2. Check connecting line.
MS150121/00E 2015-07 | Troubleshooting | 75