CleaverBrooks FLX Operation, Service And Parts Manual page 70

Packaged boiler
Table of Contents

Advertisement

Chapter 4
MNEMONIC
FDJB
Flame Detector Junction Box
FDPS
Flow Differential Pressure Switch
FFA
Flame Failure Alarm
FFL
Flame Failure Light
FFR
Flame Failure Relay
FGR
Flue Gas Recirculation
FGRCDTD
Flue Gas Recirculation Cool Down Time Delay
FGRCPS
Flue Gas Recirculation Cam Position Switch
FGRFM
Flue Gas Recirculation Fan Motor
FGRFMS
Flue Gas Recirculation Fan Motor Starter
FGRFMSI
Flue Gas Recirculation Fan Motor Starter Interlock
FGRMVLS
Flue Gas Recirculation Manual Valve Limit Switch
FGRTD
Flue Gas Recirculation Time Delay
FORS
First Out Reset Switch
FPM
Feed Pump Motor
FPMS
Feed Pump Motor Starter
FPR
Feed Pump Relay
FPS
Feed Pump Switch
FRI
Firing Rate Interface
FRP
Firing Rate Potentiometer (O2 Trim)
FS
Flow Switch
FSS
Fuel Selector Switch
FSSM
Flame Signal Strength Meter
FVEL
Fuel Valve Energized Light
FVL
Fuel Valve Light
FVR
Fuel Valve Relay
FWC
Feed Water Control
FWVT
Feed Water Valve Transformer
G
Green (Color Of Pilot Light)
GGL
Gauge Glass Light
GOL
Gas Operation Light
GOR
Gas-Oil Relay
GOS
Gas-Oil Switch
GOR
Gas-Oil Relay
GPS
Gas Pressure Sensor
GPV
Gas Pilot Valve
GPVV
Gas Pilot Vent Valve
GR
Gas Relay
GSSV
Gas Sensor Solenoid Valve
GVEL
Gas Valve Energized Light
GVTS
Gas Valve Test Switch
HATC
High Ambient Temperature Control
HBWTC
High Boiler Water Temperature Control
HBWTL
High Boiler Water Temperature Light
HFAV
High Fire Air Valve
HFGV
High Fire Gas Valve
HFL
High Fire Light
HFOV
High Fire Oil Valve
HFPS
High Furnace Pressure Switch
HFS
High Fire Switch
HFS-A
High Fire Switch - Air
HGPL
High Gas Pressure Light
HGPR
High Gas Pressure Relay
HGPS
High Gas Pressure Switch
HHFL
Header High Fire Light
4-6
DESCRIPTION
G
H
Figure 4-1: Electrical Nomenclature (Continued)
MNEMONIC
H/LWA
High Low Water Alarm
HLC
High Limit Control
HLFC
High-Low Fire Control
HLPC
High Limit Pressure Control
HLTC
High Limit Temperature Control
HMC
Header Modulating Control
HOPL
High Oil Pressure Light
HOPR
High Oil Pressure Relay
HOPS
High Oil Pressure Switch
HOLC
Header Operating Limit Control
HOTL
High Oil Temperature Light
HOTR
High Oil Temperature Relay
HOTS
High Oil Temperature Switch
HPCO
High Pressure Cutoff
HSPC
High Steam Pressure Control
HSPL
High Steam Pressure Light
HSPR
High Steam Pressure Relay
HSTC
High Stack Temperature Control
HSTL
High Stack Temperature Light
HSTS
High Stack Temperature Switch
HWAR
High Water Alarm Relay
HWC
High Water Control
HWCO
High Water Cutoff
HWL
High Water Light
(I.C.)
Instantaneously Closed
(I.O.)
Instantaneously Open
IL
Ignition Light
INT
Interval (Timer)
IR
Ignition Relay
IT
Ignition Transformer
JPP
Jackshaft Position Potentiometer
LAMPS
Low Atomizing Media Pressure Switch
LASPS
Low Atomizing Steam Pressure Switch
LDL
Load Demand Light
LDPS
Low Differential Pressure Switch
LDS
Low Draft Switch
LFAV
Low Fire Air Valve
LFGV
Low Fire Gas Valve
LFHTD
Low Fire Hold Time Delay
LFL
Low Fire Light
LFOV
Low Fire Oil Valve
LFPS
Low Fire Pressure Switch
LFR
Low Fire Relay
LFS
Low Fire Switch
LFS-A
Low Fire Switch - Air
LFS-F
Low Fire Switch - Fuel
LFS-G
Low Fire Switch - Gas
LFS-O
Low Fire Switch - Oil
LFTC
Low Fire Temperature Control
LGPL
Low Gas Pressure Light
LGPR
Low Gas Pressure Relay
LGPS
Low Gas Pressure Switch
LIAPS
Low Instrument Air Pressure Switch
LLPC
Low Limit Pressure Control
Sequence Of Operation
DESCRIPTION
I
J
L
750-177

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents