Facing Material; Splatter Guard - Heat & Glo LUX42 Installation Manual

Hide thumbs Also See for LUX42:
Table of Contents

Advertisement

B. Facing Material
• Metal front faces may be covered with non-combustible
materials only.
• Facing and/or fi nishing materials must not interfere
with air fl ow through louvers, operation of louvers or
decorative fronts, or access for service.
• Facing and/or fi nishing materials must never overhang
into the glass opening.
• Observe all clearances when applying combustible
materials.
• Seal joints between the fi nished wall and appliance top
and sides using a 300ºF minimum sealant. Refer to
Figure 10.5.
WARNING! Risk of Fire! DO NOT apply combustible
materials beyond the minimum clearances. Comply with
all minimum clearances to combustibles as specifi ed in
this manual. Overlapping materials could ignite and will
interfere with proper operation of decorative fronts and
louvers.
COMBUSTIBLE MATERIAL
0 IN.
0 in.
NON-COMBUSTIBLE
Figure 10.5 Non-combustible Facing Diagram
A
MODEL
in.
LUX36
61
1549
LUX42
67
1702
0 IN.
A
B
BOARD
B
mm
in.
mm
57-5/8
1464
62-5/8
1591
Heat & Glo • LUX36, LUX42 Installation Manual
C. Splatter Guard
The splatter guard is a piece of corrugated material
used to protect the appliance during the installation
process before fi nishing work on the whole hearth is
complete. Splatter guards may be factory installed or
accompany the decorative front of the appliance, de-
pending on the fi replace model. Splatter guards must
be removed before appliance is fi red.
WARNING! Risk of Fire! Close the ball valve before in-
stalling the splatter guard to prevent accidental lighting.
Remove the splatter guard before lighting the appliance.
1. Fold top fl ap along scored lines.
2. Slide side tabs into slots by sides of glass.
Figure 10.6
• 2287-980 Rev. L
2287-980 Rev. L • 4/16
43