MODELS:
Leave this manual with party responsible for use
and operation.
CAUTION! Risk of Cuts or Abrasions. Wear protective
gloves and safety glasses during installation.
CAUTION: Logs are fragile, handle with care.
NOTICE: To simplify the installation process, use
Figure 1 to positively identify each individual log
before beginning installation.
2
1
Figure 1. Log Identification
LOG #1: Locate the cutout on Log #1, place it over the pilot hood and set the log on the left side of the firebox. Rotate Log
#1 clockwise until it contacts log pin A and the firebox wall. Ensure that the end of Log #1 is in contact with the air scoop.
See Figure 3.
LOG #2: Set Log #2 on the burner between pins B and C. Rotate the log counter clockwise until it contacts both pins B and
C and slide it back until it contacts the Air Scoop. Ensure Log #2 is not covering any ports. See Figure 4.
A
1
Figure 3. Log #1 Installed
Heat & Glo • LOGS-2531, LOGS-2532, LOGS-2533 Installation Instructions • 2532-935 Rev. C • 3/19
LOGS-2531, LOGS-2532, LOGS-2533
SUPREME-I25-IFT, SUPREME-I30-IFT, SUPREME-I35-IFT, I30X-AU
Installation Instructions
3
5
4
MODEL: SUPREME-I25-IFT
SUPREME-I25-IFT SRV LOGS
LOG ID
SRV PART #
1
SRV2531-711
2
SRV2531-712
3
SRV2531-713
4
SRV2531-714
5
SRV2531-715
PILOT HOOD
A
Figure 2. Empty Firebox with Front Hearth Installed
C
2
SHOULDER SCREW
Figure 4. Log #2 Installed
MOLDED LOG #
31-1
31-2
31-3
31-4
31-5
AIR SCOOP
C
B
AIR SCOOP
B
1