G. PVLP-SLP and PVI-SLP Information
This section provides specifi c detail for installation of
LUX36 and LUX42 models with approved power vent kits.
Follow instructions included with the PVLP-SLP or PVI-
SLP power vent kits.
See Table 4.1 below for approved Power Venting options
for LUX models.
WARNING! Risk of Fire! Use ONLY Hearth & Home
Technologies-approved power venting systems with this
appliance. Use of power venting systems not approved
by Hearth & Home Technologies may cause fi replace to
overheat.
PVLP-SLP
LUX36
APPROVED
LUX42
APPROVED
Table 4.1
WARNING! Risk of Explosion! Follow instructions to
set draft fl ow. Incorrect setting may impair burner perfor-
mance and/or cause delayed ignition.
The power vent draft fl ow must be adjusted and set per
the specifi cations in Table 4.2. Refer to the instructions
provided with the PVLP-SLP and PVI-SLP for more specifi c
information.
Setting the PVLP-SLP Baffl e Adjustment:
Note: The air baffl e may be adjusted after installation.
The baffl e adjustment screw can be accessed by removing
the front cap cover.
•
If the burner fl ames are short, active, and jumping, turn
the bolt counterclockwise (open). check the burner
fl ames and adjust the baffl e again as necessary until
the fl ames are stable, strong, and steady.
•
If the burner fl ames are tall, lifting, fl oating, and ghost-
like, the baffl e is too far open and MUST be closed.
Turn bolt clockwise.
•
If the pilot continuously sparks and does not become
steady, the baffl e may need to be opened. The require-
ments in Table 4.2. must still be met.
Distance from PVLP-SLP
to Appliance
2-15 ft.
16-39 ft.
Greater than 40
Table 4.2
PVI-SLP
APPROVED
APPROVED
Allowable Baffl e
Minimum
Maximum
1-1/2 in.
2-1/2 in.
Closed
1-1/2 in.
Closed
Heat & Glo • LUX36, LUX42 Installation Manual
PVI-SLP: The baffl e adjustment is measured using the
holes on the indicator bar of the PVI-SLP baffl e. This bar
raises as the baffl e is opened and lowers as the baffl e is
closed. Adjust the baffl e by turning the screw located in the
motor enclosure. See Figure 4.12 and 4.13.
Baffl e Adjustment Setting
LUX36
LUX42
Table 4.3
INDICATOR BAR
ADJUSTMENT BOLT
Figure 4.12 Baffl e Adjustment Location - PVI-SLP
INDICATOR BAR
ADJUSTMENT HOLES
Figure 4.13 Baffl e Adjustment - PVI-SLP
• 2287-980 Rev. L
•
2287-980 Rev. L • 4/16
PVI-SLP
3 Holes Visible
2 Holes Visible
25