REMOTE ADMINISTRATION & MAINTENANCE PROCEDURES
SECTION 400-096-600
SEPTEMBER 1992
STEP
1
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter Program Number 56
Press CR.
3
Enter Port Number
Refer to the System Record Sheet and enter the
required port number,
Example: Port 01, enter 0 1.
4
Press # Key
(if single port
The system will display any previously entered group number (1 ~ 4).
Refer to the System Record Sheet and change as required.
Example: Change to 4, enter 4.
5
To Exit Program/Store Data
A)
To store data, press CR.
B)
Continue returning to Step 3 until all data has been entered
for this program.
C)
To exit this program, press # # CR.
STEP
1
Enter the Data Dump Mode
At the >MODE prompt, enter D U M P CR.
2
To Output Program Data
Enter P R G
CR
= Program number or A L L for all programs.
3
To Stop Printout at Any Time
Enter DELETE CR.
4
To Exit the Dump Mode
Enter Q U I T CR.
TABLE RM-BH
PROGRAM 56
LCR STATION GROUP ASSIGNMENT
ACTION
or
*
.
entry in Step 3).
TABLE RM-BI
PROGRAM DATA DUMP
ACTION
-56-
DISPLAY/PRINTOUT
>MODE PROG
P
P 56
P56
P56 01
P56 01# 1 4
P56 01# 1 4
P56 ##
P
DISPLAY/PRINTOUT
>MODE DUMP
D
D PRG
D
>MODE