INSTALLATION-WIRING DIAGRAMS
SECTION 400-096-209
SEPTEMBER 1992
TO PEKU W/FEMALE
BRIDGING
CONNECTOR
W-BL
26
1
BL-W
1
2
W-O
27
3
O-W
2
4
W-GN
28
5
GN-W
3
6
W-BR
29
7
BR-W
4
8
W-S
30
9
S-W
5
10
R-BL
31
11
BL-R
6
12
R-O
32
13
O-R
7
14
R-GN
33
15
GN-R
8
16
R-BR
34
17
BR-R
9
18
R-S
35
19
S-R
10
20
BK-BL
36
21
BL-BK
11
22
BK-O
37
23
O-BK
12
24
BK-GN
38
25
GN-BK
13
26
BK-BR
39
27
BR-BK
14
28
BK-S
40
29
S-BK
15
30
Y-BL
41
31
BL-Y
16
32
Y-O
42
33
O-Y
17
34
Y-GN
43
35
GN-Y
18
36
Y-BR
44
37
BR-Y
19
38
Y-S
45
39
S-Y
20
40
V-BL
46
41
BL-V
21
42
V-O
47
43
O-V
22
44
V-GN
48
45
GN-V
23
46
V-BR
49
47
BR-V
24
48
V-S
50
49
S-V
25
50
66M150 SPLIT BLOCK
FIGURE 9-24
MDF WIRING/PEKU AMPLIFIED TWO-CO LINE CONFERENCE
CLIPS
VT1
1
VR1
2
CIRCUIT 1 TO EKT
DT1
3
DR1
4
VT2
5
PEKU, CIRCUIT 2 VOICE PAIR
VR2
6
DT2
7
NOT USED
DR2
8
VT3
9
PEKU, CIRCUIT 3 VOICE PAIR
VR3
10
DT3
11
NOT USED
DR3
12
VT4
13
VR4
14
CIRCUIT 4 TO EKT
DT4
15
DR4
16
VT5
17
VR5
18
CIRCUIT 5 TO EKT
DT5
OR HDCB
19
DR5
20
VT6
21
VR6
22
CIRCUIT 6 TO EKT
DT6
23
DR6
24
VT7
25
VR7
CIRCUIT 7 TO EKT
26
DT7
27
OR DSS
DR7
28
VT8
29
VR8
CIRCUIT 8 TO EKT
30
DT8
OR DSS
31
DR8
32
OCA T1 (OT)
33
OCA R1 (OR)
34
OT2
35
CIRCUIT 2
OR2
36
OT3
37
CIRCUIT 3
OR3
38
OT4
39
OR4
CIRCUIT 4
40
OT5
41
CIRCUIT 5
OR5
42
OT6
43
CIRCUIT 6
OR6
44
OT7
45
CIRCUIT 7
OR7
46
OT8
47
CIRCUIT 8
OR8
48
49
NOT USED
50
CUSTOMER SUPPLIED
LINE REPEATERS (SEE NOTE 2)
PORT A (CENTRAL OFFICE SIDE)
PORT B (SUBSCRIBER SIDE)
(SEE NOTE 3)
NOTES:
1.
This feature is availble with Releases
3 and 4.
2.
Amplifier or Repeater must have
Automatic Gain Control and be FCC-
Registered from Part 68.
3.
Refer to Manufacturer's Installation
Documentation for Amplifier or Line
Repeater Pin numbering.
4.
Connect to PEKU circuits only, do
not connect to PESU, PSTU, or
PDKU circuits.
SYSTEM PROGRAMS
• Program 10-3, circuit assignments:
PROGRAM 10-3
KEY/LED
LED 01, ON
LED 02, ON
LED 03, ON
LED 04, ON
• Program 10-1, key LED 19 and 20 ON.
• Program 15-5, enable appropriate CO
lines for tandem connection.
• Program 78-2, enable appropriate CO
lines if amplified DISA is required.
• Program 10-2, key LED 18 and 19 ON.
9-28
TWO-WAY AMPLIFIER
OR
TO 117VAC
PEKU SLOT
PEKU PORT
PEKU
POSITION
NUMBER
CIRCUIT
A = 09
CKT2
2nd
B = 10
CKT3
A = 17
CKT2
3rd
B = 18
CKT3
A = 25
CKT2
4th
B = 26
CKT3
A = 33
CKT2
5th
B = 34
CKT3