Toshiba Strata DK24 Installation And Maintenance Manual page 324

Hide thumbs Also See for Strata DK24:
Table of Contents

Advertisement

REMOTE ADMINISTRATION & MAINTENANCE PROCEDURES
SECTION 400-096-600
SEPTEMBER 1992
STEP
1
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2
Enter Program Number
Refer to the record sheet and enter the desired program number.
Example: Program 30, enter 3 0, press CR.
3
Enter Port Number
Refer to the System Record Sheet and enter the desired
port number(s). Example: 0 4.
4
Press # key.
5
Enter the Desired Button/LED Number
Example: Button/LED 01, enter: 0 1.
6
To Change Button/LED Status
Refer to the System Record Sheet and change the Button/LED
status, if required (Y or N).
Example: Enter Y.
7
To Advance to Next Button/LED
Press SPACE (repeat step 6 if necessary).
8
To Store Data of Button/LED Status Change
Press CR.
Reenter Steps 3 thru 8 to review or change data.
9
To Exit Program/Store Data
A)
To exit this program, press # #, then press CR.
B)
Continue returning to Step 2 until all Type 2 programs
are completed.
10
To Exit the Program Mode
Press # # CR.
11
To Enter Another Mode,
Press
D U M P CR
T E S T CR
M E S G CR
R E P T CR
NOTE:
Y =button/LED(s) "ON", N = button/LED(s) "OFF", U = button/LED(s) "ON" some parts and "OFF" other parts.
TABLE RM-K
TYPE 2 PROGRAM PROCEDURE EXAMPLE
(PROGRAMS: 17, 20, 30, 31, 35, 40, 41, 43, 79, 81 ~ 89)
ACTION
or Port Range
(data dump)
(test)
(LCD messages)
(speed dial)
>MODE PROG
P
P 30
*
P30
P30 04
P30 04#
P30 04# 01 N
P30 04# 01 N Y
P30 04# 01 Y-
P10
P10 ##
P
>MODE
D
T
(no prompt)
R
-20-
DISPLAY/PRINTOUT
(Note)
LED "ON"
Button/LED Number
Port Number
Program Number

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk96Strata dk56