TBI
TERMINAL
STRIP
FIGURE 6-12
PIOUS PCB SWITCH/JUMPER, OPTION LOCATION
ured for the appropriate hardware options
(refer to Paragraph 10.10 and Section 400-
096-208).
NOTE:
Ensure the component side of the PCB is
facing right when installing it in the KSU.
3) Insert the PIOU or PIOUS into the last slot
(Slot 06 for DK24, Slot 08 for DK56, and Slot
14 for DK96 ), and apply firm, even pressure
to ensure proper mating of connectors.
4) After installing the PIOU or PIOUS, gently pull
the PCB outward. If the connectors are prop-
erly mated, a slight resistance will be felt.

10.30 PIOU and PIOUS Wiring

10.31 Refer to Peripheral Equipment Installation,
J3
SW1
SW3
TTY
CCITT
W4 NORMAL OPEN
SMDR
W3
BELL
NORMAL CLOSED
SW2
CD4
MAKE
W1
BREAK
MAKE
W2
BREAK
K2
K1
PIOUS
W4 NOT FACTORY
INSTALLED FOR BELL
MODEM SPECIFICATION
IMDU
P2
P1
P3
OPTIONAL IMDU PCB
REMOTE MAINTENANCE
MODEM
BACKPLANE
CONNECTOR
Section 400-096-208, and Wiring Diagrams, Sec-
tion 400-096-209, for PIOU and PIOUS wiring/
interconnecting details.
10.40 PIOU and PIOUS Programming Over-
view
10.41 The following programming parameters may
be specified for the PIOU and PIOUS:
Program 03
Specify Code 41 for the slot that will support a
PIOU or PIOUS.
Program 10-2
Use to activate External Page with All Call Page
(with access code 39 only, not with All Call Page
button).
Program 60
Use to assign SMDR options.
Program 77-1
Use to assign relay control and IMDU options.
6-25