............Fix canopy (lower duct cover assembly) to
chimney structure with 12 screws.
15. Assemble the lower trim strips (those with hooks)
to the lower vent cover assembly.
Cut the upper trim strips to length to fit the upper
duct cover assembly.
Assemble the upper trim strips to the upper duct
cover assembly.
Lower
tab
16. Check all light bulbs to make sure they are secure
in their sockets.
Turn power on in service panel.
Check lights and blower operation.
17. Install filter.
If range hood does not operate:
Check that the circuit breaker is not tripped or the
house fuse blown.
Disconnect power supply. Check that wiring is
correct.