Glide EGL-E30AS EGL-E36AS Model number: Numéro de modèle: ____________________________________ Número de modelo: Serial number: Numéro de série : _____________________________________ Número de serie: Date of Purchase: Date d’achat : Fecha de compra: Sales Dealer: Détaillant: Distribuidorr: JAN06.0101 READ AND SAVE THESE INSTRUCTIONS...
Page 2
E page F page S page APPROVED FOR RESIDENTIAL APPLIANCES PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
Important safety Notice ... 4 Electrical & Installation requirements ... 5 Electrical requirements ... 5 Before installing the hood ... 5 List of Materials ... 6 Parts supplied: ... 6 Parts not supplied ... 6 Dimensions and clearances ... 7 Installation Instructions ...
READ AND SAVE THESE INSTRUCTIONS CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B.
ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer’s responsibility: • To contact a qualified electrical installer. • To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.
PARTS SUPPLIED: • Blower unit housing • Hood canopy • Metal filter x 1 • Halogen light bulb x 2 • Hardware Packet: Transition Allen spanner x 1 Lower bracket x 2 Upper Bracket x 2 Use, Care and Installation guide Template Cloth 2,9x9,5 screws x 2 (to fix the transition)
Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version). Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless (recirculating) version.
Duct pieces Equivalent number lenght x used 3 1/4 ” x 10” 1 Ft. Rect., straight 6 ” Round,, 1 Ft. straight 7", 8” 1 Ft. Round,, straight 3 1/4 ” x 10” 15 Ft. x ( Rect.90° elbow 3 1/4 ” x 10” 9 Ft.
1. If possible, disconnect and move freestanding or slide-in range from cabinet opening to provide easier access to rear wall. Otherwise put a thick, protective covering over countertop, cooktop or range to protect from damage or dirt. Select a flat surface for assembling the unit.
Page 11
8. Fit the blower unit housing inside the cabinet through the bottom opening. Check that fixing springs goes over the bottom panel.. Bottom opening Fixing Bottom springs panel 9. Apply two brackets (one per side) to the blower unit housing... Upper bracket ...
Page 12
... tighten securely the two screws on upper brackets, check that blower housing is now well blocked, then, from the inside of the hood, fix definitively the lower brackets with one screw each. Adjusting screws Upper + lower bracket definitive fixing screws 10.
12. Electrical connection WARNING Electrical Shock Hazard Warning: Turn off power circuit at the service panel before wiring this unit. 120 VAC, 15 or 20 Amp circuit required. ELECTRICAL GROUNDING INSTRUCTIONS THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE.
Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.
CLEANING The cooker hood should be cleaned regularly internally and externally. For cleaning use the supplied cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks.
Issue After installation, the 1. The power source is not turned ON. unit doesn’t work? 2. The power line and the cable locking connector is not connecting properly. 3. The switch board and control board wirings are disconnected. 4. The switch board or control board is defective.
Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr’s Authorized Agents. What is Not Covered: Consumable parts such as light bulbs, filters, and fuses.
Need help?
Do you have a question about the Glide EGL-E30AS and is the answer not in the manual?
Questions and answers