  • Page 1 JAN06.0101...
  • Page 2 E page F page S page APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES. IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner.
  • Page 3: Table Of Contents

    www.zephyronline.com Important safety Notice ..............4 Electrical & Installation requirements ..........5 Electrical requirements .............. 5 Before installing the hood ............5 List of Materials ................. 6 Parts supplied: ................6 Parts not supplied ..............6 Dimensions and clearances.............. 7 Installation Instructions ..............
  • Page 4: Important Safety Notice

    READ AND SAVE THESE INSTRUCTIONS CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPORS. WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B.
  • Page 5: Electrical & Installation Requirements

    www.zephyronline.com ELECTRICAL REQUIREMENTS Important: Observe all governing codes and ordinances. It is the customer’s responsibility: • To contact a qualified electrical installer. • To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 —...
  • Page 6: List Of Materials

    PARTS SUPPLIED: • Blower unit housing • Hood canopy • Metal filter x 1 • Halogen light bulb x 2 • Duct covers • Duct Cover support bracket (3 pieces to assemble) • Hardware Packet: 4x8 screws x 4 (to assemble Duct cover support bracket) 6x70 screws x 2 (to fix duct cover support bracket) 10x60 wall anchors x 2 (to fix duct cover support bracket) 5x45 screws x 3 (2 to fix lower support bracket + 1 to fix blower unit)
  • Page 7: Dimensions And Clearances

    www.zephyronline.com 13" 6/16 36" - 42" 8"min* ceiling 2"min 1/2" 11" 12/16 10" 1/2 12" Ducting and conduit 12" area passage(Duct 50" 3/16 bends are not considered) 30" 14/16 20"min Side 46" 4/16* Side Cabinet Cabinet 27" 9/16* 36" - 42" 26"...
  • Page 8: Installation Instructions

    Closely follow the instructions set out in this manual. All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined. VENTING METHODS The hood is equipped with a transition B for discharge of fumes to the outside (Ducting version). Should it not be possible to discharge cooking fumes and vapour to the outside, the hood can be used in the Ductless (recirculating) version.
  • Page 9: Installation - Ductwork Calculation Sheet

    www.zephyronline.com Duct pieces Equivalent number Duct pieces Equivalent number lenght x used Total lenght x used Total 3 1/4 ” x 10” 1 Ft. 6" Round 30 Ft. x ( Rect., wall cap straight with damper 6 ” Round,, 1 Ft. 6”...
  • Page 10: Installation

    stud finder. Mark the center of the studs with a ASSEMBLING THE DUCT COVER SUPPORT vertical line to the right and left of the marked BRACKET (3 PARTS): fastener location. The three parts should be fixed with 4 screws, the support extension is adjustable and should correspond 8.
  • Page 11 www.zephyronline.com 14. Note: disregard this step if intending to install a in- c. Connect all cables: line blower. Purchase and install the Internal blower (see paragraph „Before installing the hood - Parts not supplied“ for model reference). 15. If supplied dismounted for shipping, assemble the lower part of the hood with the internal blower housing: a.
  • Page 12: 20. Electrical Connection

    20. Electrical connection 16. Hang hood with the 2 mounting hooks. WARNING WARNING Excessive Weight Hazard - Use two or more people Electrical Shock Hazard to move and install range hood. Failure to do so can Warning: Turn off power circuit at the service panel result in back or other injury.
  • Page 13 www.zephyronline.com 25. Install duct cover with 4 screws. Note: Upper Duct Cover may be placed upside down Conduit to hide (or unhide) ventless slots. J-Box cover Duct cover support bracket Duct cover support bracket Upper duct cover Connect black wire from service panel to black or red in junction box, white to white and green to green-yellow.
  • Page 14: Description Of The Hood & Controls

    1 Control panel 2 Grease filter 3 Grease filter release handle 4 Halogen lamp (position and nr. of lamps may vary) 5 Hood canopy 6 Duct cover 7 Air outlet (used for Ductless version only) CONTROLS Use the high suction speed in cases of concentrated kitchen vapours. It is recommended that the cooker hood suction is switched on for 5 minutes prior to cooking and to leave in operation during cooking and for another 15 minutes approximately after terminating cooking.
  • Page 15: Maintenance

    www.zephyronline.com Prior to any maintenance operation ensure that the cooker hood is disconnected from the power supply. CLEANING The cooker hood should be cleaned regularly internally and externally. For cleaning use a cloth moistened with a neutral liquid detergents. Avoid abrasive detergents. Warning: Failure to carry out the basic standards of the cleaning of the cooker hood and replacement of the filters may cause fire risks.
  • Page 16: Trouble Shooting

    Issue Cause What to do After installation, the 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit doesn’t work? unit’s power is ON. 2. The power line and the cable locking 2. Check the power connection with the connector is not connecting properly.
  • Page 17: Warranty

    Product damaged through negligence, misuse, abuse, accident. Improper installation and failure to follow installation instructions. When product is used commercially or other than its intended purpose. Damaged because of improper connection with equipment of other manufacturers. Repaired or modified by anyone other than Zephyr’s Authorized Agents. What is Not Covered: Consumable parts such as light bulbs, filters, and fuses.
  • Page 18: List Of Part And Accessories

    Part Description Part# halogen bulb, 12V 20 W Z0B-0013 metal filter Part Description Part# Ductless Recirculating Kit ZRC-00AT Z0F-C060 charcoal replacement filter Z1C-00AT duct cover extension kit internal blower - 600 cfm EBI-600A in-line blower - 1100 cfm EBN-1100A...