RECOMMENDED
PRESSURE:
10 to 23 bar (140 to 320 p.s.i.). Select the
operating air pressure within this range for best
fastener performance.
DO NOT EXCEED 23 bar (320 p.s.i.).
4. TECHNICAL DATA
q NOISE
A-weighted single-event sound power level
A-weighted single-event emission sound
pressure level at work station
These values are determined and documented
in accordance to EN12549 : 1999.
w VIBRATION
Vibration characteristic value = 6.6 m/s
These values are determined and documented
in accordance to ISO 8662-11.
This value is a tool-related characteristic value
and does not represent the influence to the
hand-arm-system when using the tool. An
influence to the hand-arm-system when using
the tool will, for example, depend on the
gripping force, the contact
pressure force, the working
direction, the adjustment of
mains supply, the workpiece,
the workpiece support.
5. APPLICATIONS
*Framing
*Sheathing
*Decking
*Subflooring
*Hard wood
OPERATING
------ LWA, 1s, d 92.81 dB
------- LpA, 1s, d 83.35 dB
2
3. AIR SUPPLY AND
CONNECTIONS
WARNING
Read
section
INSTRUCTIONS".
DO NOT USE ANY POWER SOURCE EXCEPT
AN AIR COMPRESSOR
The tool is designed to operate on compressed
air. Do not operate the tool on any other
combustible gases (e.g., oxygen, acetylene, etc.)
since there is the danger of an explosion. For this
reason, absolutely do not use anything other than
an air compressor to operate the tool.
10 bar
140 psi
OPERATE WITHIN THE PROPER AIR
PRESSURE RANGE
The tool is designed to operate within an air
pressure range of 10 to 23 bar (140 to 320 p.s.i.).
The pressure should be adjusted to the type of
the work being fastened. The tool shall never be
operated when the operating pressure exceeds
23 bar (320 p.s.i.).