Download Print this page

Max HN100(CE) Operating And Maintenance Manual page 11

High pressure framing tool

Advertisement

e Swing Magazine Cover closed.
r Close the Door.
Check that Door Latch engages. (If it does not
engage, check that the nail heads are in the
slot on the Nose).
TEST OPERATION
q Adjust the air pressure at 10 bar (140 p.s.i.)
and connect the air supply.
w Without touching the trigger, depress the
contact arm against the work-piece.
Pull the trigger. (The tool must fire the
fastener.)
e With the tool off the work-piece, pull the
trigger.
Then depress the contact arm against the
work-piece. (The tool must fire the fastener.)
r Adjust the air pressure as much as the lowest
possible according the length of fastener and
the hardness of work-piece.
MODEL IDENTIFICATION
CONTACT TRIP
The common operating procedure on "Contact
Trip" tools is for the operator to contact the work
to actuate the trip mechanism while keeping the
trigger pulled, thus driving a fastener each time
the work is contacted. This will allow rapid
fastener placement on many jobs, such as
sheathing, decking and pallet assembly.
All pneumatic tools are subject to recoil when
driving fasteners. The tool may bounce, releasing
the trip, and if unintentionally allowed to recontact
the work surface with the trigger still actuated
(finger still holding trigger pulled) an unwanted
second fastener will be driven.
CONTACT TRIP WITH ANTI-DOUBLE FIRE
MECHANISM
(US patent 5597106, UK patent 2286790)
Identified by RED TRIGGER.
SEQUENTIAL TRIP
The Sequential Trip requires the operator to hold
the tool against the work before pulling the trigger.
This makes accurate fastener placement easier,
for instance on framing, toe nailing and crating
applications. The Sequential Trip allows exact
fastener location without the possibility of driving
a second fastener on recoil, as described under
"Contact Trip".
The Sequential Trip Tool has a positive safety
advantage because it will not accidentally drive a
fastener if the tool is contacted against the work-
or anything else-while the operator is holding the
trigger pulled.
SEQUENTIAL TRIP
Identified by ORANGE TRIGGER.
11
ENGLISH

Advertisement