TOOL AIR FITTINGS:
This tool uses a 1/4˝ N.P.T. male plug. The inside
diameter should be 7mm (.28") or larger. The
fitting must be capable of discharging tool air
pressure when disconnected from the air supply.
RECOMMENDED
PRESSURE:
5 to 7 bar (70 to 100 p.s.i.). Select the operating
air pressure within this range for best fastener
performance.
DO NOT EXCEED 8 bar (120 p.s.i.).
4. TECHNICAL DATA
q NOISE
A-weighted single-event sound power level
A-weighted single-event emission sound
pressure level at work station
These values are determined and documented
in accordance to EN12549 : 1999.
w VIBRATION
Vibration characteristic value
These values are determined and documented
in accordance to ISO 8662-11.
This value is a tool-related characteristic value
and does not represent the influence to the
hand-arm-system when using the tool. An
influence to the hand-arm-system when using
the tool will, for example, depend on the
gripping force, the contact
pressure force, the working
direction, the adjustment of
mains supply, the workpiece,
the workpiece support.
5. APPLICATIONS
General constuction works including siding,
decking, panel sheathing
Crating
Making wooden pallets
OPERATING
------ LWA, 1s, d 93.78 dB
------- LpA, 1s, d 86.64 dB
3.6 m/s
2
3. AIR SUPPLY AND
CONNECTIONS
WARNING
Read
section
INSTRUCTIONS".
DO NOT USE ANY POWER SOURCE EXCEPT
AN AIR COMPRESSOR
The tool is designed to operate on compressed
air. Do not operate the tool on any other
highpressure gas, combustible gases (e.g.,
oxygen, acetylene, etc.) since there is the danger
of an explosion. For this reason, absolutely do not
use anything other than an air compressor to
operate the tool.
OPERATE WITHIN THE PROPER AIR
PRESSURE RANGE
The tool designed to operate within an air
pressure range of 5 to 7 bar (70 to 100 p.s.i.).
The pressure should be adjusted to the type of
the work being fastened. The tool shall never be
operated when the operating pressure exceeds 8
bar (120 p.s.i.).