Canon iPF605 Service Manual page 162

Hide thumbs Also See for iPF605:
Table of Contents

Advertisement

Chapter 4
5) Having installed the flexible cable retainer, align and flatten the flexible cables.
6) Attach the flexible guide sheet[1] over the flexible cable while bumping its rear side against the side plate.
d) Multi Sensor Recalibration
Since multi sensor has individual electrical specificity, the following are recalibrated at the factory, namely, the optical axis of the sensor, the sensor gain for meas-
uring the printhead height and sensor calibration. Accordingly, carry out the following adjustments in the service mode whenever replacing the carriage unit or
multi sensor.
* The multi sensor reference plate(QL2-1561-000:PLATE, REFLECTION, MULTI-SENSOR) must be replaced at the same time whenever the carriage or the multi
sensor is being replaced.
- Service mode : SERVICE MODE > ADJUST > GAP CALIB.
- Service mode : SERVICE MODE > ADJUST > PRINT PATTERN > OPTICAL AXIS
Media type : Photo glossy paper
Media size : Media having a width equal too larger than that of A2-size paper
4-24
[1]
F-4-52