TECHNICAL DATA

Voltage
Permissible load at
100% duty cycle
60% duty cycle
45% duty cycle
Setting range (DC)
Open circuit voltage
Open circuit power
Efficiency
Power factor
Control voltage
Enclosure class
Weight kg
Dimensions lxbxh
Application classification
Voltage
Permissible load at
100% duty cycle
80% duty cycle
60% duty cycle
Setting range (DC)
Open circuit voltage
Open circuit power
Efficiency
Power factor
Control voltage
Enclosure class
Weight kg
Dimensions lxbxh
Application classefication
These welding power sources conform to the requirements of IEC 974- -1.
Duty cycle
The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-
tain load without overloading the welding power source.
Enclosure class
The IP code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked IP 23 is designed for indoor and outdoor use.
Application class
The symbol
indicates that the power source is designed for use in areas with increased
electrical hazard.
ba32d12e
LAW 420/420W
400--415V, 3∼50Hz
280 A/28 V
350 A/32 V
400 A/34 V
40 A/16 V--400 A/34 V
53--58 V
590/790W
0,74
0,86
42 V, 50/60 Hz
IP 23
200/214
800x640x835
LAW 520/520W
400--415V, 3∼50Hz
400 A/34 V
450 A/37 V
500 A/39 V
40 A/16 V--500 A/39 V
53--60 V
670/870 W
0,78
0,90
42 V, 50/60 Hz
IP 23
225/239
800x640x835
- - 33 - -
LAW 420/420W
230/400--415/500V, 3∼50Hz
230/440--460V, 3∼60Hz
280 A/28 V
350 A/32 V
400 A/34 V
40 A/16 V--400 A/34 V
53--58 V
640/840W
0,76
0,84
42 V,50/60 Hz
IP 23
201/215
800x640x835
LAW 520/520W
230/400--415/500V, 3∼50Hz
230/440--460V, 3∼60Hz
390 A/33,5 V
435 A/36 V
500 A/39 V
40 A/16 V--500 A/39 V
53--60 V
720/920 W
0,78
0,90
42 V,50/60 Hz
IP 23
227/241
800x640x835