Table A-13 (Cont.). VR319-CA and VR319-C4 Monitor Description
– Front porch
– Horizontal period
– Pixels displayed
– Sync pulse
Vertical rate timing
– Active video time
– Back porch
– Blanking interval
– Front porch
– Horizontal period
– Lines displayed
– Sync pulse
Power
– Power supply type
– ac input
– Frequency
– Power consumption
Fuse
Table A-14. VR319-CA and VR319-C4 Monitor Operating Conditions
1
Temperature range
Temperature change rate
Relative humidity
Maximum wet-bulb temperature
Minimum dew-point temperature
Altitude
1
Reduce maximum temperature by 1.8°C for each 1,000 meter (1.0°F for each 1,000 ft) increase in
altitude.
0.2670 ns

14.1519
s
10.6806
1.3351 ns

14.4915
s
0.467011 ns

0.551922
s
0.042455 ns

15.0434
s
14.4915
0.042455 ns
Switch mode ac to dc converter
Automatic voltage select
47 to 63 Hz
Approximately 123 watts
250 V: 5 A
6.35 by 31.8 mm (0.25 by 1.25 in) slow blow
10°C to 40°C (50°F to 104°F)
11° (52°F) per hour maximum
10% to 90% noncondensing
28°C (82°F)
2°C (36°F)
2,400 m (8,000 ft) maximum