7
Control panel settings B-Control
7.1
List of parameters
Tab.10 Information list
Information
°C
°C
°C
7.2
Setting the parameters
Fig.35
Setting the heating
7615193 - v01 - 09072015
7.1.1 Information menu
Description
Status
Sub-status
Heating water temperature (°C)
The
symbol flashes
Domestic hot water temperature (°C)
The
symbol flashes
If no domestic hot water sensor connected: display — — —
Outside temperature (°C)
The
symbol flashes.
Burner status
Energy meter on the heating water circuit
The
symbol flashes.
The displayed value flashes.
Energy meter on the domestic hot water circuit
The
symbol flashes.
The displayed value flashes.
Information on the boiler not available
7.2.1 Setting the heating water temperature
1. Turn the settings button
Note
If the heating water temperature set point is lower than 16 °C,
without an outside temperature sensor, the heating is switched off
automatically.
The heating starts up again only to ensure frost protection if the
outside temperature sensor shows a value of less than 3°C.
Note
This setting is possible regardless of the display.
Set the heating water temperature set point if no temperature sen
sor is connected.
Set the desired room temperature if an outside temperature sen
MW-3000243-1
sor is connected.
7 Control panel settings B-Control
.
EFU