7.5

Disassembling and Reassembling the Unit

Motorola recommends the service technician follow a prescribed disassembly sequence to access
specific items or components of the unit. This product is an efficiently designed package that
incorporates the physical overlap and integration of some modular components. Refer to the
Disassembly Sequence Flowchart for a suggested path to reach specific components.
NOTE: In some cases, the technician may not need to remove certain components to reach others.
7.6

Disassembly Sequence Flowchart

Battery Cover
Battery
Back Housing
Front Housing with
Flip Assembly
Main Keypad
Flip Assembly
7.7

Assembly/Disassembly Procedures

NOTE: Installation procedures to be performed in reverse of disassembly except where noted.
Screws used to assemble the i580 are: 1 antenna screw, T-4 drive; 6 housing assembly screws, four
T-6 drive, two T4 drive.