Technician Test Procedures - Motorola IDEN I580 Field Service Manual

Basic and field level test procedures digital multi-service, data-capable portable
Hide thumbs Also See for IDEN I580:
Table of Contents

Advertisement

BASIC LEVEL TEST MODES AND PROCEDURES: Technician Test Procedures
24. Scroll down to highlight Band Info, and then press View to view the Band Info display. This
screen displays the primary and secondary control channels: Pri Band: 02 for 800 MHz; Sec
Band: 02 for 800 MHz and 04 for 900 MHz.
25. Press Back to return to the Trace Mode display.
26. Scroll down to highlight Bandmap, and then press View to view the Bandmap display. This
screen displays the currently selected regional bandmap.
27. Press Back to return to the Trace Mode display.
28. Scroll down to highlight Hardware, and then press View to view the Hardware display. This
screen displays RF Xtal (RF Crystal), a factory-tuned parameter that adjusts the output
frequency; Xtal Offset (RF Crystal Warp offset), which is derived during frequency
compensation; and Level Set (Level Set value), which regulates the transmit output power of the
unit.
29. Press Back to return to the Trace Mode display.
30. Scroll down to highlight Fatal Err/#, and then press View to view the Fatal Err/# display. This
screen displays the Fatal Error log. This log contains a count of any fatal errors logged during
the unit's automatic self test.
31. Press Back to return to the Trace Mode display.
32. Scroll down to highlight Flags, and then press View to view the Flags display. This screen
displays the error log, which contains any errors logged by the unit software.
33. Press Back to return to the Trace Mode display.
34. Scroll down to highlight Coin Cell, and then press View to show the Preset Charging Voltage on
line 1 and Current Battery Voltage on line 2.
35. Press Back to return to the Trace Mode display.
36. Scroll down to highlight CE Status, and then press OK to view accessory type connected to the
unit.
37. Press Back to return to the Trace Mode display.
6.3

Technician Test Procedures

Technician Tests usually require special equipment to test the functionality of the components in the
unit.
The following tests check the software functionality of the unit:
Codeplug Help
Codeplug Troubleshooting
40
68P80401P05

Advertisement

Table of Contents
loading

Table of Contents