2. Extend antenna whip fully.
3. Hold unit stationary while tugging at collar until antenna assembly releases.
4. Insert tweezers into the antenna housing port, grab the edge of antenna tube and pull it out.
7.11.2 Install:
1. Carefully push antenna collar into position.
2. Insert antenna assembly with whip fully extended, contact toward interior of unit. Push firmly
until fully seated.
3. Pull antenna whip in and out to check for correct operation. Reinsert T-4 screw and tighten
clockwise to 0.5 in/lb.
4. Align and insert new valence plug. Must be flush with surface.
68P80401P05
PREPARING FOR FIELD LEVEL TESTING: Remove Antenna
3 3
Figure 7-5.