10. Enter the appropriate values in the following RF zone fields. These values might be different,
depending on your bandmap. Use the arrow keys to move between fields and the keypad to
enter values.
Table 7-1. RF Zone Fields and Values
Field
Carr. #
Mon. Freq
Offset
Format
Mon.
Gen
11. Press the DISP key to return to the Display zone. You now are ready to begin testing.
7.4
Disassembling and Reassembling the 530 Unit
Motorola recommends the service technician follow a prescribed disassembly sequence to access
specific items or components of the unit. The i530 product is an efficiently designed package that
incorporates the physical overlap and integration of some modular components. Refer to the i530
Disassembly Sequence flowcharts for a suggested path to reach specific components.
NOTE: In some cases, the technician may not need to remove certain components to reach others.
68P80400P65-O
PREPARING FOR FIELD LEVEL TESTING: Disassembling and Reassembling the i530 Unit
Value
Choose the appropriate carrier number from your bandmap. The
Mon. Freq. field displays the associated frequency.
Choose the appropriate monitor frequency from your bandmap. The
Carr. # field displays the associated carrier frequency.
800 MHz = +45 MHz; 900 MHz = +39 MHz
iDEN
40 dB RF I/O
-070 dBm RF I/O