DISPLAYS, MESSAGES, AND ALERTS: Power-Down Sequence
3.2

Power-Down Sequence

To power down the unit, press and hold the Power key until the unit begins powering down.
3.3

Messages

3.3.1

Self-Test Errors

The following table contains the list of self-test non-reset errors. These errors are displayed as SELF
CHECK ERROR YXXXX (YXXXX represents the identifier for that error).
Table 3-1. Self-Test Errors
Y
XXXX
0
0001
0
0002
3.3.2

Self-Test Reset Errors

The following table contains the list of self-test reset errors. These errors are displayed as SELF
CHECK FAIL YXXXX (YXXXX represents the identifier for that error).
Table 3-2. Self-Test Reset Errors
Y
XXXX
0
0100
0
0200
0
0400
0
0800
0
1000
0
2000
0
4000
F
4000
F
8000
F
8002
:
0800
12
Description of Error
Non-reset error log
Codeplug error log
Description of Error
RAM failure
Data lines failure
Address line failure
Codeplug corruption/invalid
Flash checksum error
Reset error logging
Codeplug mismatch
Ergo pre-self-test codeplug error
Ergo pre-self-test invalid device or device failure
Ergo pre-self-test invalid device or device failure
FDI-related error
68P80401P05