Registration/Call Test - Motorola IDEN I580 Field Service Manual

Basic and field level test procedures digital multi-service, data-capable portable
Hide thumbs Also See for IDEN I580:
Table of Contents

Advertisement

8.4

Registration/Call Test

Use this test on a unit having any of the following symptoms: No Service failures, Please Wait...
Registering failures. (Use a reference unit to get a baseline.)
Note: For 900 MHz verification, please perform the BER Test. May require ordering additional option for test.
Contact Motorola Customer Service (see Appendix A).
Set up the R-2660 for iDEN
Mobile operation, and connect the
unit to the RF IN/OUT connector.
See Figure 7-1 on page 7-3.
Power up
the unit. Enter initial
Registration mode (see
Operating the R-2660). Press Start.
The Call SEQ: 1 thru 6 lights up
when the unit has
registered.
Pass
Verify the
unit can complete
an interconnect call. Press
End/Home until unit displays
Ready. Press Interconnect (3:1 or 6:1)
and Start on the R-2660. Press Send
on the unit. The Call SEQ: 1 thru 8
lights up when the unit has
entered Phone
mode.
Pass
68P80401P05
FIELD LEVEL TEST MODES AND PROCEDURES: Registration/Call Test
Notes:
1.
See the Strong Signal Environment section.
2.
Master reset can be completed on the unit by pressing Menu,
Settings, Security.
3.
Registration and calls might take over 1 minute to complete.
4.
Make sure the R-2660 is set to a frequency in the radio bandmap.
Fail
R-2660 calibration, setup,
for Half Rate if attempting
Fail
a 3:1 phone call or Full Rate if
attempting a 6:1 phone
Unit passed test. Look for
system, coverage, accessory,
or software problems.
Verify the
OK
and cable continuity.
Fix, if necessary.
Verify the
unit is programmed
call. Repeat the
test.
Pass
Fail
Pass
Perform
BER Test.
Fail
Replace the
Main board.
63