Operation - Yunca Gas jervois Operation, Maintenance And Warranty Manual

Freestanding
Table of Contents

Advertisement

OPERATION

How to Light Your YUNCA JERVOIS
Refer to Fig 5.
1. First read all the instructions for the heater.
2. Check that the control knob "A"(Fig 5) is in the off position, the thermostat knob "B" is turned to
its Highest setting (7) and back burner control "C" should be in the off position.
3. Turn off electric power at the wall.
4. Turn the knob "A" slightly anti-clockwise to stop. Push the control knob "A" fully down and turn
left from OFF to IGN, hold for 5-15 seconds. Continuing to hold down, turn the knob "A" further
anti-clockwise to pilot mark (you will hear a click). Observe pilot light by looking through front
door. The pilot light is visible under the left-hand end of the log set.
5. When the pilot is lit, continue pushing in knob for further 20 seconds to allow safety thermocouple
to heat up. Slowly release knob and pilot flame should remain lit. If it goes out repeat steps 4 and
5. If there is difficulty using control "A" an accessory "Arthritic Control Aid" (6645) is available.
6. The pilot control knob "A" can now be turned fully left to the ON position to light the front burner.
7. Turn electric power on and the fan to low speed.
8. After the front burner has been turned on, turn the back burner on, by pushing in knob "C" and
turning Anti-Clockwise to maximum position.
Allow both burners to run for 30 minutes to bring the room up to temperature.
19-07-05
Fig 5: Control Panel.
Page 9 of 20
Operation Instructions for Jervois Freestanding Gas Heater March 2002

Advertisement

Table of Contents
loading