Carrier 59SP5A Installation, Start-Up, Operating And Service And Maintenance Instructions page 78

100 series

Advertisement

..q
oo
_o
o
NO PREVIOUS
CODE
- Stored
codes
are
erased
after 72 hours.
Run system
through
a heating
or cooling
cycle
to
check
system.
12
BLOWER
ON AFTER
POWER
UP -
(115V
OR 24V)
- Normal
operation.
Blower
runs for 90 seconds,
if unit is
powered
up during
a call for heat
(R-W
closed)
or when
(R-W
opens)
during
the
blower
on-delay
period.
13
LIMIT
CIRCUIT
LOCKOUT
- Lockout
occurs
if the limit or flame
rollout
is open
longer
than
3 minutes.
Control
will auto-
reset
after 3 hours.
See code 33.
14
IGNITION
LOCKOUT
- System
failed
to
ignite
gas and prove
flame
in 4 attempts.
Control
will auto-reset
after 3 hours.
See
status
code
34.
21
GAS
HEATING
LOCKOUT
- Turn off
power
and wait 5 minutes
to retry.
Check
for:
-
Stuck
closed
gas valve
relay on control.
-
Miswire
or short to gas valve
wire.
22
ABNORMAL
FLAME-PROVING
SIGNAL
Flame
is proved
while
gas valve
is de-
energized.
Inducer
will run until fault
is
cleared.
Check
for:
-
Stuck
open
or leaky
gas valve.
23
PRESSURE
SWITCH
DID NOT OPEN
-
Check
for:
-
Obstructed
pressure
tube.
-
Pressure
switch
stuck
closed.
24
SECONDARY
VOLTAGE
FUSE
IS OPEN
Check
for:
-
Short circuit
in secondary
voltage
(24V)
wiring
including
thermostat
leads.
Disconnect
thermostat
leads to isolate
short circuit.
31
LPS or HPS PRESSURE
SWITCH
DID
NOT CLOSE
OR REOPENED
- If opens
during
blower
on-delay
period,
blower
will
come
on for the selected
blower
off-delay.
If LPS opens
longer
than
5 minutes,
inducer
shuts
off for 15 minutes
before
retry.
If HPS remains
open
for one minute
after gas valve
closes
the furnace
will shut
down
and retry. If HPS fails to close
on
three
successive
cycles
the furnace
will
lockout
for 3 hrs before
retry.
Check
for:
-
Proper
vent
sizing.
- Air leak between
vestibule
and
blower
compartment.
-
Low inlet gas pressure
(if LGPS
used).
-
Disconnected
or obstructed
pressure
tubing.
-
Defective
or miswired
pressure
switches
-
Excessive
wind.
-
Plugged
condensate
drain
-
Water
in vent piping,
possible
sagging
pipe
-
Restricted
vent.
-
Defective
Inducer
motor.
-
Low inducer
voltage
(115 VAC)
33
LIMIT CIRCUIT
FAULT
- Indicates
the
limit, flame
rollout
is open.
Blower
will run
for 4 min. or until open switch
remakes
whichever
is longer.
If open
longer
than
3
min, code changes
to lockout
#7.
If open
less than
3 min. status
code #4 continues
to flash
until blower
shuts off.
Flame
rollout
switch
requires
manual
reset.
Check
for:
-
Loose
blower
wheel.
-
Defective
switch
or connections.
-
Dirty filter
or restricted
duct system.
-
Improper
gas input adjustment
-
Improper
limit switch
or no limit gasket.
34
IGNITION
PROVING
FAILURE
- If flame
is not sensed
during
the trial for ignition
period,
the control
will repeat
the ignition
sequence
3 more times
before
lockout
#14
occurs.
If flame
signal
is lost during
the
blower
on-delay
period,
blower
will come
on for the selected
blower
off-delay.
Check
the following
items first before
proceeding
to the next step.
-
Gas valve
turned
off.
-
Manual
shut-off
valve.
-
Green/Yellow
wire
MUST
be connected
to furnace
sheet
metal.
-
Flame
sensor
must not be grounded.
To determine
whether
the problem
is in
the gas valve,
igniter,
or flame
sensor
the
system
can be operated
in the component
test mode
to check
the igniter.
First
remove
the R thermostat
connection
from
the control
and initiate
the component
test
sequence.
Does
the igniter
glow
orange/white
by the end of the 15 second
warm-up
period?
Y --s
Unplug
igniter
harness
from control
and
initiate
another
component
test
sequence.
Check
for 115V
between
pin
1 and NEUTRAL-L2
on the control.
Was
115V
present
for the 15 second
period?
YES
NO
..-q
Reconnect
the R thermostat
lead and set
thermostat
to call for heat.
Connect
voltmeter
across
gas valve
connections.
Does
gas valve
receive
24V?
I
Does
gas valve
open and allow
gas to
flow?
YES
I
DO the main burners
ignite?
I YES
YES
I
Uothe
main burners
on?
stay
No
.
I
I
Repeat
call for heat
and check
flame
INOI
sensor
current
during
trial for ignition
period.
Is the DC microamps
below
0.5?
_ YES
I
Clean flame
sensor
with fine steel wool
I
m
I
and recheck
current.
Nominal
current
is
4.0 to 6.0 microamps.
I
s current
near typical
value?
YES
,NO,
I
ill main burners
ignite and stay on?
YES
[Fixed.
l
45
CONTROL
CIRCUITRY
LOCKOUT
Auto-reset
after
1 hour lockout
due
to:
-
Flame
circuit
failure.
-
Gas valve
relay stuck
open.
-
Software
check
error.
Reset
power
to clear
lockout.
Replace
control
if code
repeats.
Replace
furnace
control.
Check
for continuity
in the
harness
and igniter.
Replace
defective
component.
Check
connections.
If OK,
replace
control.
Check
that all gas valves
are
turned
on.
Replace
valve.
Check
for:
-
Inadequate
flame
carryover
or rough
ignition.
-
Low inlet gas pressure.
-
Proper
firing rate.
Allow
blower
to come
on and
repeat
test to check
for
intermittent
operation.
Check
connections
and
retry.
If current
is near typical
value
(4.0-6.0
nominal)
and burners
will not stay on, replace
control.
Replace
electrode.
]
Replace
furnace
control.
]