Carrier 59SP5A Installation, Start-Up, Operating And Service And Maintenance Instructions page 14

100 series

Advertisement

ii
NOTE:
The condensate
trap extends
below the side of the casing
in the
horizontal
position.
A minimum
of 2 in. (51
mm)
of
clearance
is required
between
the
casing
side
and the
furnace
platform
for the trap to extend out of the casing in the horizontal
position.
To Relocate
the Condensate
Trap:
• Remove
the knockout
in the casing for the Casing
Grommet.
• Install the grommet
in the casing.
• Orient the furnace in the desired
position.
• Allow for 2 in. (51 mm) of clearance
underneath
the furnace
for
the condensate
trap and drain line.
• Fig. 10 shows
the condensate
trap and tubing before
and after
relocation
in the horizontal
right position.
• Fig. 11 shows
the condensate
trap and tubing before and after
relocation
in the horizontal
left position.
• Refer to the appropriate
figure to begin
the trap conversion.
• Remove
the relief tube from the condensate
trap.
• Remove
the screw that secures
the condensate
trap to the
collector
box.
• Remove
the trap.
• Remove
the relief tube from the port on the collector
box. It is
not necessary
to remove
the tube from the inducer
assembly.
For Horizontal
Left only:
• Remove
the pressure
switch robe from the front pressure
switch
and discard
the tube. A new pressure
switch
tube is shipped
in
the loose parts bag.
For Horizontal
Right only:
• The pressure
switch tube location
is not modified.
• Loosen the clamp around
the inlet of the vent elbow on the
inducer.
• Remove
the plugs from the collector
box and set aside. Do Not
Discard Plugs.
For Horizontal
Left only:
• Remove
the middle
and right plug from the ports at the bottom
of the collector
box.
For Horizontal
Right only:
• Remove
the plug to the right of the condensate
trap.
• Refer to the appropriate
figure to begin the trap conversion,
• Install the plugs previously
removed
from the collector
box in
the ports where the condensate
trap was removed.
• Install the trap over the ports on the lower side of the collector
box.
• Secure the trap to the collector
box with the screw.
• Connect
the relief tube to the condensate
trap to the relief port of
the condensate
trap.
• If necessary,
slide the relief tube in the inducer
stand-offs
to
adjust the position
of the tube.
• Connect
the relief tube to the relief port of the condensate
trap,
For Horizontal
Left only:
• Connect
the new pressure
switch tube to the port on the front
pressure
switch. Route the tube through
the stand-offs
on the
inducer
assembly
and connect to the port on the collector
box.
Trim off any excess tube to avoid sags or kinks in the tube.
• Rotate the vent elbow to the desired
position
and tighten
the
clamp 15 in.-lbs.
• Refer to Condensate
Drain section for information
how to install
the condensate
drain,
Condensate Trap
Relief Port
Vent Pipe Clamp
Elbow Clamp
Collector Box
Plugs
Elbow
Collector Box
Plug
Condensate Trap
Relief Port
Pressure Switch
Port
UPFLOW TRAP CONFIGURATION
1 & 2 Stage Units
Fig. 8 - Upflow Trap Configuration
Outlet
Al1307
14