Carrier 59SC2A Product Data

Carrier 59SC2A Product Data

Comfort 100 series single-stage 4-way multipoise condensing gas furnace

Advertisement

59SC2A
Comfort™ Series Single---Stage
4---Way Multipoise
Condensing Gas Furnace
Series 100
The 59SC2 Multipoise Comfort Series Condensing Gas Furnace
features energy efficiency of 92.1% AFUE gas efficiency and
workhorse PSC blower motor. This gas furnace also features
4- -way multipoise installation flexibility, and is available in eight
model sizes. The 59SC2 can be vented for direct vent/two- -pipe,
ventilated combustion air, or single- -pipe applications. All units
meet California Air Quality Management District emission
requirements, are design certified in Canada, and are certified for
mobile/manufactured home use.
STANDARD FEATURES
S 4- -Way multipoise design for upflow, downflow or horizontal
installation.
S Installation flexibility with a 360- -degree rotating elbow.
S More than twelve different venting options, including optional
through- -the cabinet downflow and horizontal venting.
S Ideal condensing furnace height 35" cabinet: short enough for
Product Data
taller coils, but still allows enough room for service.
S Silicon Nitride Power Heatt Hot Surface Igniter.
S Aluminized- -steel primary heat exchanger.
S Stainless steel condensing secondary heat exchanger.
S High- -quality corrosion- -resistant prepainted steel cabinet with
hemmed edges for safety.
S Factory- -configured ready for upflow applications.
S Direct- -vent/sealed combustion, single- -pipe venting or
ventilated combustion air.
S PSC blower motor, single- -speed inducer motor, and
single- -stage gas valve.
S Self- -diagnostics with SuperBrite LED.
S Approved for Twinning applications (60- -14 through 120- -60
sizes, only)
S Propane convertible (see accessory list).
S Approved for Manufactured Housing/Mobile Home applications
with MH accessory kit.
A11263
S Convenient Air Purifier and Humidifier connections.
S Residential installations may be eligible for consumer financing
through the Retail Credit program.
S Certified to leak 2% or less of nominal air conditioning CFM
delivered when pressurized to 1- -in. water column with all
present air inlets, air outlets, and condensate drain port(s) sealed.
S 10 year parts and 20 year heat exchanger limited warranty to the
original purchaser upon timely registration.
S Limited warranty period is five years for parts and twenty years
for the heat exchanger if not registered within 90 days of
installation.{
* For owner occupied, residential applications.
Jurisdictions where warranty benefits cannot be conditioned on registra-
{
tion will receive registered limited warranty benefits.
1

LIMITED WARRANTY*

CERTIFIED

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 59SC2A and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Carrier 59SC2A

  • Page 1: Limited Warranty

    59SC2A Comfort™ Series Single---Stage 4---Way Multipoise Condensing Gas Furnace Series 100 Product Data taller coils, but still allows enough room for service. S Silicon Nitride Power Heatt Hot Surface Igniter. S Aluminized- -steel primary heat exchanger. S Stainless steel condensing secondary heat exchanger.
  • Page 2: Features And Benefits

    Monoport Burners — The burners are specially designed and Power Heatt Igniter — Carrier’s unique SiN igniter is not only finely tuned for smooth, quiet combustion and economical physically robust but it is also electrically robust. It is capable of operation.
  • Page 3: Specifications

    SPECIFICATIONS Heating Capacity and Efficiency 040-10 060-10 060-14 080-16 080-20 100-14 100-20 120-20 Input High Heat (BTUH) 40,000 60,000 60,000 80,000 80,000 100,000 100,000 120,000 Output High Heat (BTUH) 39,000 58,000 58,000 78,000 78,000 97,000 97,000 117,000 Efficiency AFUE % (ICS) 92.1 92.1 92.1...
  • Page 4: Parts List

    MODEL NUMBER NOMENCLATURE 1 - 2 7 - 9 11 - 12 15 - 16 Family Htg. Stages Tier Effy. Major Series Htg. Cap. Motor Width Minor Series Voltage Airflow 08 - 800 CFM Family 10 - 1000 CFM 12 - 1200 CFM S - Single Stage 14 - 1400 CFM T - Two Stage...
  • Page 5 ACCESSORIES Venting Accessories Part Number Used With Notes Vent Kit - Through the Cabinet KGADC0101BVC 2-in. KGAVT0701CVT See Venting Tables Vent Terminal - Concentric 3-in. KGAVT0801CVT See Venting Tables 2-in. KGAVT0101BRA See Venting Tables 1, 2 Vent Terminal Bracket 3-in. KGAVT0201BRA See Venting Tables 1, 2...
  • Page 6 AIR DELIVERY - - CFM (BOTTOM RETURN WITH FILTER) EXTERNAL STATIC PRESSURE (IN.W.C.) RETURN-AIR RETURN AIR SPEED UNIT SIZE CONNECTION TAPS Black 1100 1055 1010 Yellow 040---10 SIDE/BOTTOM Blue Black 1340 1295 1245 1190 1130 1065 1005 Yellow 1035 1010 060---10 SIDE/BOTTOM Blue...
  • Page 7 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) Table 1 – Maximum Equivalent Vent Length - - Ft. (M) 0 to 4500 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 8 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) Table 2 – Deductions from Maximum Equivalent Vent Length - - Ft. (M) Pipe Diameter (in): 1-1/2 2-1/2 Mitered 90º Elbow (2.4) (2.4) (2.4) (2.4) (2.4) Medium Radius 90º Elbow (1.5) (1.5) (1.5) (1.5)
  • Page 9 MAXIMUM EQUIVALENT VENT LENGTH - - FT. (M) (CONTINUED) Table 3 – Maximum Equivalent Vent Length - - Ft. (M) 4501 to 10,000 Ft. (0 to 1370 M) Altitude NOTE: Maximum Equivalent Vent Length (MEVL) includes standard and concentric vent termination and does NOT include elbows. Use Table 2 - Deductions from Maximum Equivalent Vent Length to determine allowable vent length for each application.
  • Page 10 MAXIMUM ALLOWABLE EXPOSED VENT LENGTHS INSULATION TABLE - - FT. (M) Maximum Length of Uninsulated and Insulated Vent Pipe-Ft (M) No Insulation 3/8-in. (9.5 mm) Insulation 1/2-in. (12.7 mm) Insulation Single Stage Pipe Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Pipe Diameter-inches (mm) Winter Design Furnace Length in...
  • Page 11: Return Air Temperature

    RETURN AIR TEMPERATURE This furnace is designed for continuous return- -air minimum temperature of 60_F (15_C) db or intermittent operation down to 55_F (13_C) db such as when used with a night setback thermometer. Return- -air temperature must not exceed 80_F (27_C) db. Failure to follow these return air limits may affect reliability of heat exchangers, motors and controls.
  • Page 12 Carrier cased coil is used. It is combustion air to be drawn in through the outer pipe.
  • Page 13: Typical Wiring Schematic

    MEDIA FILTER CABINET 25-5/8" (651mm) 24-1/4” 23-5/8" (616mm) (600mm) Opening with Flanges Bent 23-1/8” 23-3/8” (588mm) (594mm) Opening Duct Side Furnace Side 23-3/4” (603mm) " Centerline Screw Slots Media Filter (146mm) Cabinet 17" (432mm) 16" (406mm) 16" (406mm) 20" (508mm) 21"...
  • Page 14: Dimensional Drawing

    DIMENSIONAL DRAWING A11593...
  • Page 15: Guide Specifications

    GUIDE SPECIFICATIONS General System Description Primary Heat Exchangers Furnish a ______________________ 4- -way multipoise gas- -fired Primary heat exchangers shall be 3- -Pass corrosion- -resistant condensing furnace for use with natural gas or propane (factory- - aluminized steel of fold- -and- -crimp sectional design and applied authorized conversion kit required for propane);...
  • Page 16 Catalog No: 59SC2A ---01PD Copyright 2012 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231 Printed in U.S.A. Edition Date: 01/12 Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Table of Contents

Save PDF