kWHr (kilo-Watt-Hour) Recording function

1~" Power position. Setup power
Set the slide-switch function-selector to the "3~Bal
measurements as mentioned in the previous "Single-Phase Power & 3-Phase
Balanced-Load Power functions" section
●To start (
) kWHr Recording, press "3~Bal
1~" and "HOLD" buttons at the
"
"
same time. Annunciator " " turns on & flashes. kWHr accumulated time (in Hour) is
displayed automatically in the secondary mini display.
●To pause (
"
"
), press "HOLD" button momentarily. Annunciator " " stops flashing
and is always on.
●To continue (
"
"
), press the "HOLD" button momentarily again. Annunciator " "
resumes flashing.