WARNING
identifies conditions and actions that could result in serious injury or even death to the user.
CAUTION
identifies conditions and actions that could cause damage or malfunction in the instrument.
This manual contains information and warnings that must be followed for operating the instrument safely and
maintaining the instrument in a safe operating condition. If the instrument is used in a manner not specified by the
manufacturer, the protection provided by the instrument may be impaired. The meter is intended only for indoor
use.
With test lead tip insulation CAP,
IEC/UL/EN61010-1 Ed.
1.1
and
CAN/CSA-C22.2 No. 61010-1-12 Ed. 3.0
25a).
In case of removing test lead tip insulation CAP, to CAT II 600V (CAT II 450V for Model 25s
Measurement Category III (CAT III) is for measurements performed in the building installation. Examples are
measurements on distribution boards, circuit-breakers, wiring, including cables, bus-bars, junction boxes, switches,
socket-outlets in the fixed installation, and equipment for industrial use and some other equipment, for example,
stationary motors with permanent connection to the fixed installation.
Measurement Category II (CAT II) is for measurements performed on circuits directly connected to the low
voltage installation. Examples are measurements on household appliances, portable tools and similar equipment.
WARNING
To reduce the risk of fire or electric shock, do not expose this product to rain or moisture. To avoid electrical shock
hazard, observe the proper safety precautions when working with voltages above 60 VDC or 30 VAC rms. These
voltage levels pose a potential shock hazard to the user. Do not touch test lead tips or the circuit being tested
while power is applied to the circuit being measured. Keep your fingers behind the finger guards of the test leads
during measurement. Inspect test leads and probes for damaged insulation or exposed metal before using the
instrument. If any defects are found, replace them immediately.
1) PRODUCT DESCRIPTION
Note: Top of the line model is used as representative for illustration
purposes. Please refer to your respective model for function
availability.
1) LCD display
2) Rotary Selector to Select additional functions
only), and to turn the Power On or Off
& 25a
3) Push-button to Select additional functions (all models), and to
switch the Power On or Off
4) Input for all functions, or otherwise specified. Red test lead for
positive (+) polarity and Black test lead for Ground reference (-)
2) SAFETY
Terms in this manual
the meter is protected, against the users, by double insulation per
3.0,
IEC/EN61010-2-030 Ed.
BM22s, BM25s,
USER'S MANUAL
does not have a physical Rotary Selector.
1.0,
IEC/EN61010-2-033 Ed. 1.0, IEC/UL/EN61010-031 Ed.
to CAT III 300V & CAT II 600V (CAT II 450V for
BM25a
& BM27s
(Models 27s & 22s
(Model 22s
(Models 27s, 25s
& 25a
only).
Model 25s
only)
Model 25s
&
&
25a) only.

Advertisement

Table of Contents
loading

Summary of Contents for Brymen BM22s

  • Page 1 BM22s, BM25s, BM25a & BM27s USER'S MANUAL 1) PRODUCT DESCRIPTION Note: Top of the line model is used as representative for illustration purposes. Please refer to your respective model for function availability. 1) LCD display 2) Rotary Selector to Select additional functions (Models 27s &...
  • Page 2: International Electrical Symbols

    INTERNATIONAL ELECTRICAL SYMBOLS Caution ! Refer to the explanation in this Manual Caution ! Risk of electric shock Earth (Ground) Double Insulation or Reinforced insulation Fuse AC--Alternating Current DC--Direct Current 3) CENELEC DIRECTIVES The instruments conform to CENELEC Low-voltage directive 2006/95/EC and Electromagnetic compatibility directive 2004/108/EC 4) OPERATION Note: All function operations described hereafter are via the Red test lead for positive (+) polarity and Black test...
  • Page 3 -Electric Field EF-Detection (Models 27s, 25s & 25a only) From AutoCheck with “Auto” being displayed, press the SELECT button momentarily 2 times to select EF- Detection feature. The meter displays “EF” when it is ready. Signal strength is indicated as a series of bar-graph segments on the display and variable beep tones.
  • Page 4 momentarily to select AC-A. The AC annunciator “ ” turns on. These ranges, like other functions, are protected up to the maximum rated voltages of the meter. -DCV & ACV functions (Model 22s only) Rotate the rotary selector to the V position selects common impedance (Hi-Z) voltage measurements. Press SELECT button momentarily toggles between DCV and ACV.
  • Page 5: Maintenance Warning

    5) MAINTENANCE WARNING To avoid electrical shock, disconnect test leads from live circuits before opening the case. Do not operate with open case. Cleaning and Storage Periodically wipe the case with a damp cloth and mild detergent; do not use abrasives or solvents. If the meter is not to be used for periods of longer than 60 days, remove the battery and store it separately Trouble Shooting If the instrument fails to operate, check battery, leads, etc., and replace as necessary.
  • Page 6 Measurement Category: Models 22s & 27s: CAT II 600V and CAT III 300V Model 25s & 25a: CAT II 450V and CAT III 300V E.M.C.: Meets EN61326 (1997, 1998/A1), EN61000- 4-2 (1995), & EN61000-4-3 (1996) In an RF Field of 3V/m: Capacitance function is not specified Other function ranges: Total accuracy = Specified accuracy + 45d...
  • Page 7 AC Voltage (Models 25a, 25s & 27s) Ohms (Models 25a, 25s & 27s) RANGE Accuracy RANGE Accuracy 50Hz -- 60Hz 2.0%+6d 600.0 6.000V, 60.00V, 450.0V 1.5%+5d 1.2%+6d 6.000k 600.0V 1.0%+4d 60.00K, 600.0K CMRR: > 60dB @ DC to 60Hz, Rs=1k 2.0%+4d 6.000M...
  • Page 8: Limited Warranty

    ------------------------------------------------------------------------ LIMITED WARRANTY BRYMEN warrants to the original product purchaser that each product it manufactures will be free from defects in material and workmanship under normal use and service within a period of one year from the date of purchase.