Maintenance and
repair

Safety inspection

Disposal

Used coolant must be disposed of properly in accordance with the relevant na-
tional and international regulations. The coolant safety data sheet may be ob-
tained from your service centre or downloaded from the manufacturer's
website.
Check the coolant level before starting to weld and while the system is still
cool.
It is impossible to guarantee that bought-in parts are designed and manufac-
tured to meet the demands made of them, or that they satisfy safety require-
ments. Use only original replacement and wearing parts (also applies to
standard parts).
Do not make any modifications, alterations, etc. to the device without the man-
ufacturer's consent.
Parts that are not in perfect condition must be replaced immediately.
When ordering, please give the precise designation and part number as
shown in the spare parts list, as well as the serial number of your device.
The manufacturer recommends that a safety inspection of the device is per-
formed at least once every 12 months.
The manufacturer recommends that the power source be calibrated during the
same 12-month period.
A safety inspection should be carried out by a qualified electrician
-
after any changes are made
-
after any additional parts are installed, or after any conversions
-
after repair, care and maintenance has been carried out
-
at least every twelve months.
For safety inspections, follow the appropriate national and international stand-
ards and directives.
Further details on safety inspection and calibration can be obtained from your
service centre. They will provide you on request with any documents you may
require.
Do not dispose of this device with normal domestic waste! To comply with the
European Directive 2002/96/EC on Waste Electrical and Electronic Equip-
ment and its implementation as national law, electrical equipment that has
reached the end of its life must be collected separately and returned to an ap-
proved recycling facility. Any device that you no longer require must either be
returned to your dealer or given to one of the approved collection and recycling
facilities in your area. Ignoring this European Directive may have potentially
adverse affects on the environment and your health!