Meandering weld-
ing currents
10
Double the open circuit voltage of a power source can occur between the
welding electrodes of two power sources. Touching the potentials of both elec-
trodes at the same time may be fatal under certain circumstances.
Arrange for the mains cable to be checked regularly by a qualified electrician
to ensure the ground conductor is functioning properly.
The device must only be operated on a mains supply with a ground conductor
and a socket with a ground conductor contact.
If the device is operated on a mains supply without a ground conductor and
using a socket without a ground conductor contact, this will be deemed gross
negligence. The manufacturer shall not be held liable for any damage arising
from such usage.
If necessary, provide an adequate earth connection for the workpiece.
Switch off unused devices.
Wear a safety harness if working at height.
Before working on the device, switch it off and pull out the mains plug.
Attach a clearly legible and easy-to-understand warning sign to the device to
prevent anyone from plugging the mains plug back in and switching it on
again.
After opening the device:
-
discharge all live components
-
ensure that all components in the device are de-energised.
If work on live parts is required, appoint a second person to switch off the main
switch at the right moment.
If the following instructions are ignored, meandering welding currents can de-
velop with the following consequences:
-
Fire hazard
-
Overheating of parts connected to the workpiece
-
Irreparable damage to ground conductors
-
Damage to device and other electrical equipment
Ensure that the workpiece is held securely by the workpiece clamp.
Attach the workpiece clamp as close as possible to the area that is to be weld-
ed.
If the floor is electrically conductive, the device must be set up with sufficient
insulating material to insulate it from the floor.
If distribution boards, twin-head mounts, etc., are being used, note the follow-
ing: The electrode of the welding torch / electrode holder that is not used is
also live. Make sure that the welding torch / electrode holder that is not used
is kept sufficiently insulated.
In the case of automated MIG/MAG applications, ensure that only an insulated
wire electrode is routed from the welding wire drum, large wirefeeder spool or
wirespool to the wire-feed unit.