SHR-2160/2162/2080/2082 USER'S MANUAL
Screen Setup
It is a window to set Brightness/Contrast/Color for the camera image of each channel.
Put the cursor on the channel that you want to adjust and set Brightness/Contrast/Color.
Once selected, the channel appears in the right PIP area. Use the œ or ƒ button to adjust
the value from 0 to 100.
If you mark
in the select CH, all the channel values will become the same as the finally
selected channel value.
"Default value" resets the current channel to the basic value of 50.
In the case of the 2080/2082, 8-channel information comes up.
5-15
English
3

Monitoring

Event Monitoring
It is possible to set to Off / 3sec / 5sec / 10sec / 20sec / 30sec / Continuous.
Off : Event Monitoring does not operate to turn to the screen where an event occurs.
3sec / 5sec / 10sec / 20sec / 30sec : Sets the duration time of screen in the Auto
Sequence mode.
Continuous : The Event Monitoring screen remains alive until you press the "Alarm"
button in the front to cancel the screen manually.
OSG Display
Date : The date is displayed on the screen when it is On, and not displayed when it is Off.
Time : The time is displayed on the screen when it is On, and not displayed when it is Off.
Cam name : The Cam name is displayed on the screen when it is on, and not displayed
when it is off.
Status : Audio/Ptz is displayed on the screen when it is on, and not displayed when it is off.
Spot Out Channel
Spot Out channel is used to let one of two monitors monitor a channel, focusing on it.
Spot Out channel supplies two functions, continuous monitoring of only one channel and
Auto Sequence to display all the channels one by one.
Auto Sequence setup ranges from Ch1 to Ch16.
In the Auto Sequence mode, Spot Out channels are displayed in turn.
Duration time for Auto Sequence is as same as set for Camera setup.
Spot Out Event Monitor
Sets if event monitoring will be executed for Spot Out channels.
Off : The event monitoring dose not operate in the Spot Out channel.
3sec / 5sec / 10sec / 20sec / 30sec : Sets the duration time of screen in the Auto
Sequence mode.
Continuous : Once scrolled down, the screen remains displayed until you delete "Alarm"
LED in the front manually.