Outside Air Kit - Quadra-Fire 810-02901 (MBK) Owner's Manual Installation And Operation

Hide thumbs Also See for 810-02901 (MBK):
Table of Contents

Advertisement

R
R R
C. Outside Air Kit Instructions
Parts Included in Kit: 1 piece of  inch x  ft. flex hose, 
hose clamps, 1 collar assembly, 1 termination cap assem-
bly, 1 air intake channel, 1 trim ring, fasteners. NOTE:
Discard air intake channel, it is not used on this appliance.
Tools Needed: Phillips head screwdriver; wire cutters;
hole saw or jig saw.
1. Attach collar assembly to appliance. Figure 19.1.
Measure distance from floor to air vent opening in
appliance and mark location on wall.
. Use saw to cut opening in wall. Cut a -1/ to  inch
(64-76mm) opening on inside wall and a  to -1/
inch (76-89mm) opening on outside of house.
4. Use hose clamp to secure flex pipe to collar assem-
bly.
5. Slide trim ring over flex pipe and run pipe through
pre-cut hole in back of appliance and through the
wall.
6. Attach hose to outside termination cap with second
hose clamp.
7. Secure termination cap to outside surface.
8. Secure trim ring to interior wall.
CAUTION
Never draw outside combustion air from:
Wall, floor or ceiling cavity
Enclosed space such as an attic or garage
Air Intake Channel
(Discard)
Hose Clamp
Collar
Assembly
Figure 19.1
January 28, 2010
Trim Ring
Flex Hose
Hose Clamp
D. Zero Clearance Trim Support Instructions
NOTE: Only for use on small size panels.
Figure 19.2 - Assembled View
1
2
Figure 19.3
Item
Front,  inch
1
Front, 5 inch
2

Cast Ring, Top & Bottom, Interchangeable
Side, 5 inch
4
Side,  inch
5
Panel Extension, 5 inch
6
Panel Extension,  inch
7
Panel Extension, Base Plate Only
8
Termination
Cap Assembly
250-7251H
Castile Pellet Insert
8
7
6

Description
5
4
Page 19