F. Feed Rate Adjustment
The fuel adjustment control rod is factory set, and should be
adequate for most fuels.
The set screw is located at the bottom of the hopper and
set loose at the factory so the fuel adjustment control rod
will slide by only loosening the wing nut. Do not re-tighten
bottom set screw.
However, if the flame height is too high or too low, you will
need to adjust the feed rate. Wait until the appliance has been
burning for 15 minutes before making your adjustments and
allow 15 minutes for feed adjustment to take effect. Make
adjustments in approximately 1/ inch increments.
1.
Loosen the wing nut. Figure 26.1.
.
Adjust the fuel adjustment control rod towards the
"+" symbol to increase the feed rate and flame height or
towards the "-" symbol, to decrease the feed rate and flame
height.
. Re-tighten the wing nut.
Wing Nut
"-"
"+"
Figure 26.1
G. Iginition Cycles
1. During each ignition cycle, it is normal to see some smoke
in the firebox. The smoke will stop once the fire starts.
. The convection blower will automatically turn on after your
appliance has reached the set temperature. This blower
transfers heat from your appliance into the room, and will
continue to run after the thermostat has stopped calling
for heat until the appliance has cooled down.
. Occasionally the appliance may run out of fuel and shut
itself down. When this happens, the red call light will
be on. To restart it, fill the hopper and press the reset
button. Figure 26.2. When you press the reset button
the red call light will go out. Release the button and the
light will come back on. You should see a fire shortly.
If not, follow the instructions on page 25, "Starting Your
First Fire".
Page 6
Heat Output
Switch
Figure 26.1
Fire Risk
Do NOT operate appliance:
• With appliance door open.
• Firepot floor open.
• Cleaning slide plates open.
Do NOT store fuel:
• Closer than required clearances to com-
• Within space required for loading or ash
Back side of Firepot
Figure 26.2 - DO NOT LEAVE FIREPOT FLOOR OPEN
250-7251H
Control Box
Red Call
Light
Fuse
Reset Button
Junction Box
WARNING
bustibles to appliance
removal.
Firepot floor left open
January 28, 2010
R
Power Cord
Outlet
Thermostat