Re-entering the Server Serial Number

After replacing the system board or clearing the NVRAM, the server serial number must be
re-entered.
1. To access RBSU, press the F9 key when prompted during POST.
2. Select the System Options menu.
3. Select Serial Number. The following warning is displayed:
WARNING! WARNING! WARNING! The serial number is loaded into the
system during the manufacturing process and should NOT be
modified. This option should ONLY be used by qualified service
personnel. This value should always match the serial number
sticker located on the chassis.
Press the Enter key to clear the warning.
4. Enter the serial number and press the Enter key.
5. Press the Escape key to close the menu.
6. Press the Escape key to exit RBSU.
7. Press the F10 key to confirm exiting RBSU. The server will automatically reboot.
HP ProLiant DL585 Server Maintenance and Service Guide
Removal and Replacement Procedures
2-49