Hot-Plug Fans; Removing A Hot-Plug Fan - HP ProLiant DL585 Maintenance And Service Manual

Hide thumbs Also See for ProLiant DL585:
Table of Contents

Advertisement

Removal and Replacement Procedures

Hot-Plug Fans

The server supports redundant hot-plug fans in a 7+1 configuration.
To replace a hot-plug fan:
1. Extend the server from the rack. Refer to "Extending the Server from the Rack" earlier in
this chapter.
2. Remove the access panel. Refer to "R emoving the Access Panel" earlier in this chapter.
3. Identify the malfunctioned fan by checking for an amber LED on the QuickFind
Diagnostic Display or on the failed fan.
4. Remove the malfunctioned fan.
Figure 2-20: Removing a hot-plug fan
2-24
HP ProLiant DL585 Server Maintenance and Service Guide