Tighten the rear thumbscrews to secure the chassis cover in place.
2.
Connect the peripheral devices to the server
3.
If a Kensington security cable was removed, connect it to the rear panel. See the security cable
4.
documentation for instructions.
Connect the server to the network. Do one of the following:
5.
Connect the Ethernet cable
o
Connect the server to the switch
o
Connect the power cord to the server.
6.
Power up the server (on page 14).
7.

Remove the system board assembly

Power down the server (on page 14).
1.
Disconnect the power cord from the AC source.
2.
Disconnect the power cord from the server.
3.
Remove the chassis cover (on page 18).
4.
It is recommended that you take a picture of the current system board cable connections for reference
5.
during server reassembly.
If the drive cage is connected to a storage controller board, disconnect the Mini-SAS cable from the
6.
board.
Disconnect all cables connected to the system board:
7.
24-pin system board power supply cable
o
SATA cable (only if an optical drive is installed)
o
Mini-SAS cable (only if the drive cage is connected to the system board)
o
Front I/O cable (pulling up the blue loop to disconnect the cable)
o
Fan cable
o
Ambient temperature sensor cable (pulling up the brown loop to disconnect the cable)
o
("Connecting peripheral
("Connecting the Ethernet
("Setting up the HP networking
devices" on page 25).
cable" on page 25).
options" on page 30).
Operations 19