Figure 50
The Runtime Loader is a feature dependent on the device Operating System and may not be
NOTE
available on all the units. The description provided in this chapter assumes that you are using HMWIN Studio
V1.80 or later. On MIPS based units, the Runtime Loader is available from version V2.65; on ARM based
units the Runtime Loader is supported from BSP version V1.52.
When you click on "System settings" you can activate the System menu in User mode, where you can set
the IP address of the panel. See the chapter
"System settings
tool" for additional information on this tool.
Once the IP address is assigned and the panel is connected to a valid network, the easiest way to install the
runtime is to download a project from the HMWIN Studio. See the chapter
"Transferring the Project to
Target" for additional information.
The normal download procedure in Studio is able to recognize the need for transferring the runtime and the
process is automatically started. As soon as the panel IP is selected from the list of available units in the
network, Studio will recognize the need for transferring the runtime, providing the information as shown in the
following figure.
Figure 51
Just click on the Install runtime button to proceed.
ACGM0195V1EN
48