Jog Frequency; Run Key Rotation Direction Selection - Mitsubishi FR - S500 Instruction Manual

Transistorized inverter
Hide thumbs Also See for FR - S500:
Table of Contents

Advertisement

2
.3.10

Jog frequency

To perform jog operation in the
external operation mode, choose
the jog operation function in input
terminal function selection, turn on
the jog signal, and use the start
signal (STF, STR) to make a start
or stop.
For the type having the RS-485
communication function, you can
choose the jog operation mode
from the parameter unit (FR-PU04)
and perform jog operation using
the
or
FWD
REV
(Can be read as the basic parameters when the FR-PU04 is connected.)
Set the frequency and acceleration/deceleration time for jog operation.
Parameter
Name
15
Jog frequency
Jog acceleration/
16
deceleration time
CAUTION
In S-shaped acceleration/deceleration pattern A, the acceleration/deceleration
time is the period of time required to reach Pr. 3 "base frequency", not Pr. 20
"acceleration/deceleration reference frequency".
The acceleration time and deceleration time cannot be set separately for jog
operation.
The value set in Pr. 15 "jog frequency" should be equal to or greater than the
Pr. 13 "starting frequency" setting.
Assign the jog signal using any of Pr. 60 to Pr. 63 (input terminal function
selection).
Related parameters
Assignment of jog signal to terminal
Acceleration/deceleration pattern S-shaped acceleration/deceleration A
Pr. 29 "acceleration/deceleration pattern" (refer to page 71)
2
.3.11
key rotation direction selection
RUN
Used to choose the direction of rotation by operating the
operation panel.
Parameter
Name
RUN key rotation
17
direction selection
Refer to
Refer to
key.
Factory Setting Setting Range
5Hz
0.5s
Pr. 60 to Pr. 63 (input terminal function selection)
(refer to page 88)
Factory
Setting
0
(page 59)
,
(page 62)
Output frequency (Hz)
Pr.20
Jog frequency
setting range
Pr.15
JOG signal
STF signal
0 to 120Hz
0 to 999s
Setting
Range
0: Forward rotation
0, 1
1: Reverse rotation
67
Forward
rotation
Pr.16
ON
ON
Remarks
Setting is enabled when
Pr. 30 = "1".
key of the
RUN
Remarks
Setting is enabled
when Pr. 30 = "1".
2

Hide quick links:

Advertisement

Table of Contents
loading