Pa-
Func-
Indica-
rame-
tion
tion
ter
84 *
85 *
86 *
87 *
88
89 *
90 *
91
92
93 *
94 *
95
96
97
98
99
Name
Setting Range
Multi-speed
setting (speed
0 to 120Hz, - - -
12)
Multi-speed
setting (speed
0 to 120Hz, - - -
13)
Multi-speed
0 to 120Hz, - - -
setting (speed
14)
Multi-speed
0 to 120Hz, - - -
setting (speed
15)
PID action
20: PID reverse action,
selection
21: PID forward action
PID
proportional
0.1 to 999%, - - -
band
PID integral
0.1 to 999s, - - -
time
PID upper limit 0 to 100%, - - -
PID lower limit 0 to 100%, - - -
PID action set
point for PU
0 to 100%
operation
PID differential
0.01 to 10s, - - -
time
Rated motor
0 to 50%, - - -
slip
Slip
compensation
0.01 to 10s
time constant
Constant-
output region
slip
0, - - -
compensation
selection
Automatic
torque boost
0.1 to 3.7kW, - - -
selection
(0.2 to 3.7kW, - - - for
(Motor
the 400V class.)
capacity)
Motor primary
0 to 50 , - - -
resistance
Minimum
Setting
Increments
0.1Hz
0.1Hz
0.1Hz
0.1Hz
1
0.1%
0.1s
0.1%
0.1%
0.01%
0.01s
0.01%
0.01s
1
0.01kW
0.01
52
Cus-
Factory
Refer
tomer
Setting
To:
Setting
- - -
61
- - -
61
- - -
61
- - -
61
20
101
100%
101
1s
101
- - -
101
- - -
101
0%
101
- - -
101
- - -
109
0.5s
109
- - -
109
- - -
109
- - -
111