Page 14
Thank you for choosing this Mitsubishi Inverter option. This instruction manual gives handling information and precautions for use of this equipment. Incorrect handling might cause an unexpected fault. Before using the equipment, please read this manual carefully to use the equipment to its optimum.
Page 15
4. Additional Instructions 4) Disposal Also note the following points to prevent an CAUTION accidental failure, injury, electric shock, etc. Assumes that incorrect handling may cause • Treat as industrial waste. an accidental failure, injury, electric shock, etc. (5) General instruction 1) Transportation and installation All illustrations given in this manual may have been drawn with covers or safety...
(1) Unpack the option unit, and ensure that the product received is as you ordered and it is intact. MITSUBISHI DC REACTOR MODEL XXXXXXXXXXXX FR-HEL- SERIAL MITSUBISHI ELECTRIC CORP. FR-HEL- H Applied motor capacity (kW) Symbol Applied Power Supply Voltage None 200V class 400V class (2) Make sure that the package includes all accessories.
Wiring Wiring (1) Remove the jumper across terminals P-P1 of the inverter and connect the reactor. • Minimize the connection cable between the reactor and inverter so that the length is within 5m. (For the size of the cable, refer to page 4) •...
Outline Dimension Drawings Outline Dimension Drawings (1) 200V Class FR-HEL-0.4K to 2.2K • MAX D Installation hole for 2-d (right side, varnish remove (front / rear side)) *1 *1 Use this portion to wire an earthing cable. Type Motor Capacity Mass (kg) FR-HEL-0.4K 0.4K...
Page 21
Outline Dimension Drawings FR-HEL-3.7K to 15K • MAX D Installation hole for 4-d (near right side, varnish remove (front / rear side)) *1 Use this portion to wire an earthing cable. Type Motor Capacity W W1 H Mass (kg) FR-HEL-3.7K 3.7K 55 92 FR-HEL-5.5K...
Page 22
Outline Dimension Drawings • FR-HEL-18.5K to 55K MAX D MAX D3 Installation hole for 4-d (near right side, varnish remove (front / rear side)) *1 *1 Use this portion to wire an earthing cable. Type Motor Capacity D2 D3 Mass (kg) FR-HEL-18.5K 18.5K 107 94...
Page 23
Outline Dimension Drawings (2) 400V Class FR-HEL-H0.4K • Terminal layout Max 60 (28) Terminal Mass (kg) Installation hole for 2-M5 Screw Size (varnish removal on the right side)* M3.5 Unit (mm) FR-HEL-H0.75K to H2.2K • Terminal layout Max D (D3) D1 1 W 2.5 Installation hole for 4-M4...
Page 24
Outline Dimension Drawings • FR-HEL-H3.7K to H7.5K Terminal layout Max D (D3) D1 1 W 2.5 Installation hole for 4-d (varnish removal on the near right side)* Type Motor Capacity D2 D3 Mass(kg) FR-HEL-H3.7K 3.7K 45 M4 FR-HEL-H5.5K 5.5K 128 100 48 M5 FR-HEL-H7.5K 7.5K...
Page 25
Outline Dimension Drawings FR-HEL-H11K to H55K • Terminal layout Max D (D3) D1 1 W 2.5 Installation hole for 4-d (varnish removal on the near right side)* Type Motor Capacity D2 D3 Mass (kg) FR-HEL-H11K 137 110 105 53 M5 FR-HEL-H15K 152 125 115 62 M5...