<Setting>
Refer to the following table and set the parameters:
Signal
Setting
Name
0
RL
1
RM
2
RH
3
RT
4
AU
5
STOP
6
MRS
7
OH
8
REX
9
JOG
10
RES
14
X14
16
X16
- - -
STR
*1 When Pr. 59 = "1 or 2", the functions of the RL, RM and RH signals change as
listed above.
*2 Actuated when the relay contact "opens".
*3 When using the REX signal, an external command cannot be used to make a
reverse rotation start.
REMARKS
One function can be assigned to two or more terminals. In this case, the function
is activated when one of the multiple terminals used for assignment turns on.
The speed command priorities are higher in order of jog, multi-speed setting (RH,
RM, RL, REX) and AU.
Use common terminals to assign multi-speeds (7 speeds) and remote setting.
They cannot be set individually.
(Common terminals are used since these functions are designed for speed
setting and need not be set at the same time.)
Functions
Low-speed operation
Pr. 59 = "0"
Pr. 59 = "1", "2" (*1)
Pr. 59 = "0"
operation command
Pr. 59 = "1", "2" (*1)
High-speed operation
Pr. 59 = "0"
Pr. 59 = "1", "2" (*1)
Second function selection
Current input selection
Start self-holding selection
Output shut-off stop
External thermal relay input (*2)
The inverter stops when the externally
provided overheat protection thermal
relay, motor's embedded temperature
relay etc. is actuated.
15-speed selection (combination with 3
speeds RL, RM, RH) (*3)
Jog operation selection
Reset
PID control presence/absence selection
PU-external operation switch-over
Reverse rotation start
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
command
Pr. 80 to Pr. 87
Remote setting
Pr. 59
(setting clear)
Middle-speed
Pr. 4 to Pr. 6, Pr.24 to Pr. 27,
Pr.80 to Pr. 87
Remote setting
Pr. 59
(deceleration)
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
command
Pr. 80 to Pr. 87
Remote setting
Pr. 59
(acceleration)
Pr. 44 to Pr. 47
Refer to page 140.
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 80 to Pr. 87
Pr. 15, Pr. 16
Pr. 75
Pr. 88 to Pr. 94
Pr. 79 (setting: 8)
(can be assigned to STR
terminal (Pr. 63) only)
89
Related Parameters