Use the connectors, cables and converter which are available on the market.
Introduced products (as of June, 2000)
*1. Connector: RJ45 connector
Example: 5-554720-3, Tyco Electronics Corporation
*2. Cable
: Cable conforming to EIA568 (such as 10BASE-T cable)
Example: SGLPEV 0.5mm
Mitsubishi Cable Industries, Ltd.
(Do not use pins No. 2 and 8 (P5S)).
*3. Commercially available converter examples
Model: FA-T-RS40 Converter (One with connector and cable is also available)
Mitsubishi Electric Engineering Co., Ltd.
<Wiring methods>
1) Wiring of one RS-485 computer and one inverter
Computer Side Terminals
Signal
Description
name
RDA
Receive data
RDB
Receive data
SDA
Send data
SDB
Send data
RSA
Request to send
RSB
Request to send
Clear to send
CSA
CSB
Clear to send
SG
Signal ground
FG
Frame ground
2) Wiring of one RS-485 computer and "n" inverters (several inverters)
Computer
RDA
RDB
SDA
SDB
RSA
RSB
CSA
CSB
SG
FG
REMARKS
*1. Make connection in accordance with the instruction manual of the computer to be
used with. Fully check the terminal numbers of the computer since they change with
the model.
*2. The inverters may be affected by reflection depending on the transmission speed or
transmission distance. If this reflection hinders communication, provide a termination
resistor. When the RS-485 connector is used for connection, a termination resistor
cannot be fitted, so use a distributor. Connect the termination resistor to only the
inverter remotest from the computer. (Termination resistor: 100 )
Cable connection and signal direction
10 BASE-T Cable
Cable connection and signal direction
10 BASE-T Cable
(*1)
SG
Station 1
Inverter
4P (Twisted pair cable, 4 pairs),
(*1)
2
0.3mm or more
SG
Station 2
Inverter
43
Inverter
RS-485 connector
SDA
SDB
RDA
RDB
SG
Termination
resistor
(*2)
SG
Station n
Inverter
1