  • Page 1 4 Inch Speed Dome Installation Manual V2.0.0 2010-01...
  • Page 2 4 Inch Speed Dome Installation Manual V2.0.0 Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to 4 Inch Speed Dome. This manual may contain several technically incorrect places or printing errors, and the content is subject to change without notice. The updates will be added into the new version of this manual.
  • Page 3: Safety Instruction

    4 Inch Speed Dome Installation Manual V2.0.0 Safety Instruction These instructions are intended to ensure that user can use the product correctly to avoid danger or property loss. The precaution measure is divided into “Warnings” and “Cautions”: Warnings: Neglecting any of the warnings may cause serious injury or death. Cautions: Neglecting any of the cautions may cause injury or equipment damage.
  • Page 4: Preparation For Installation

    4 Inch Speed Dome Installation Manual V2.0.0 Preparation for Installation Basic requirements All the electronic operation should be strict compliance with the local electrical safety regulations, fire prevention regulations and other related regulations at the installation place. Check whether all the accessories are there according to the packing list, make sure that the place and installation mode are conform to the demands, if not, please contact the supplier.
  • Page 5: Table Of Contents

    4 Inch Speed Dome Installation Manual V2.0.0 Table of Contents Table of Contents................................. 4 Chapter 1 Installation..............................5 Check Parts List ............................. 5 Installation ..............................5 Initial Settings ..............................8 DIP Switch Settings ............................9 1.4.1 Address Settings .......................... 9 1.4.2 Baud Rate Settings ........................11...
  • Page 6: Chapter 1 Installation

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 1 Installation 1.1 Check Parts List      Prior to installation, unpack the dome unit and check whether it is in good condition and all parts and accessories are included by referring to the packing list). The power supply for the speed dome is AC24V/3A or DC12V/3.3A.
  • Page 7 4 Inch Speed Dome Installation Manual V2.0.0 Mounting Groove Figure 1.2.2 In-ceiling Mounting Base Configure the dome address, baud rate and other settings through DIP switch located on the bottom board of the dome drive, as shown in Figure 1.2.3 and Figure 1.2.4. Please refer to Section 1.4 DIP Switch Settings for setting address, baud rate, communication protocol, etc.
  • Page 8 4 Inch Speed Dome Installation Manual V2.0.0 Address and protocol settings BNC analog video output Address, baud rate and protocol DIP Switch settings Network interface Power, audio in/out, alarm in/out and RS485 port RS48 +12V 1: Address and protocol settings 2: BNC analog video output 3: Address, baud rate and protocol DIP Switch settings 4: Network interface...
  • Page 9: Initial Settings

    4 Inch Speed Dome Installation Manual V2.0.0 Phillips pan head screw Ball stud Figure 1.2.5 Install Dome Figure 1.2.6 Completion of Dome Installation 1.3 Initial Settings Address code: 0 Baud rate: 2400 120Ω terminator: OFF...
  • Page 10: Dip Switch Settings

    4 Inch Speed Dome Installation Manual V2.0.0 1.4 DIP Switch Settings Figure 1.2.7 DIP Switch for Address and Protocol Settings The dome provides a DIP switch for setting the dome address, baud rate, protocol, etc. As shown in Figure 1.2.7, ON=1, OFF=0; positions 1-5 of DIP switch are used for setting the dome address, positions 6-7 for baud rate, positions 8-9 for parity and Manchester code, and position 10 is for setting the connection of 120-ohm terminator.
  • Page 11 4 Inch Speed Dome Installation Manual V2.0.0...
  • Page 12: Baud Rate Settings

    4 Inch Speed Dome Installation Manual V2.0.0 1.4.2 Baud Rate Settings The positions 6-7 of DIP switch are used for setting the baud rate of dome, respectively as 2400bps, 4800bps, 9600bps and 19200bps. For baud rate out of the above range, the default setting is 2400bps. Refer to the following table: Baud Rate 2400 4800...
  • Page 13 4 Inch Speed Dome Installation Manual V2.0.0 The alarm provides the relay output (no voltage), and the external power supply is required when it connects to the alarm device. For DC power supply (left diagram), the input voltage must be within the range of 12VDC, 30mA. For AC power supply, the external relay must be used (right diagram) so as to prevent damages to the unit and avoid risk of electric shock.
  • Page 14: Chapter 2 Mounts Dimension

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 2 Mounts Dimension 2.1 Long-arm Wall Mount     St u d St u d...
  • Page 15: Short-Arm Wall Mount

    4 Inch Speed Dome Installation Manual V2.0.0 2.2 Short-arm Wall Mount S tu d 2.3 Corner Adapter S t u d S t u d...
  • Page 16: Pole Adapter

    4 Inch Speed Dome Installation Manual V2.0.0 2.4 Pole Adapter S t u d 2.5 Pendant Adapter  ...
  • Page 17: Chapter 3 Wall Mounting Applications

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 3 Wall Mounting Applications 3.1 Mounting Components      Wall Mount Applicable to indoor/outdoor pendant domes.  Mounting Accessories Nuts and Flat Washers  Pendant Adapter...
  • Page 18: Wall Mounting Instructions

    4 Inch Speed Dome Installation Manual V2.0.0 3.2 Wall Mounting Instructions The wall mounting is applicable to the indoor/outdoor solid wall construction which should comply with the following mounting requirements:  The wall must be thick enough to install the expansion screws. ...
  • Page 19 4 Inch Speed Dome Installation Manual V2.0.0 Step3: Install dome to the mount Feed cables through the opening on top of the back box, screw the back box into the threads in the mount, and then use M3 screws to secure the dome.
  • Page 20: Chapter 4 Corner Mounting Applications

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 4 Corner Mounting Applications 4.1 Mounting Components  Wall Mount Applicable to the indoor/outdoor pendant domes with the use of corner adapter, wall adapter or pole adapter.  Corner Adapter For use with the wall mount in the corner mounting applications. ...
  • Page 21: Corner Mounting Instructions

    4 Inch Speed Dome Installation Manual V2.0.0 4.2 Corner Mounting Instructions    The corner mounting is applicable to the indoor/outdoor 90° solid corner construction which should comply with the following mounting requirements:  The wall must be thick enough to install the expansion screws. ...
  • Page 22 4 Inch Speed Dome Installation Manual V2.0.0 Step2: Secure the wall mount to the corner Apply four hex screws with the spring washers to the corner adapter through the wall mount and gasket. When tightening the screw, it is better to compress the spring washer firstly and then rotate half a round so as to maintain Note: required waterproof effect without damaging the threads.
  • Page 23: Chapter 5 Pole Mounting Applications

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 5 Pole Mounting Applications 5.1 Mounting Components  Wall Mount Applicable to indoor/outdoor pendant domes with the use of corner adapter, wall adapter or pole adapter.  Pole Adapter For use with the wall mount in the pole mounting applications.
  • Page 24: Pole Mounting Instructions

    4 Inch Speed Dome Installation Manual V2.0.0  Stainless Steel Straps For use with the pole adapter, with the following dimensions selectable: φ59-82mm, φ84-108mm, φ103-127mm, φ130-152mm, φ155-178mm, φ180-203mm, φ194-216mm; Customized dimensions can also be provided according to user’s demand.  Mounting Accessories Hex Screws (M8×30) and Spring Washers ...
  • Page 25 4 Inch Speed Dome Installation Manual V2.0.0  The diameter of pole must be constituent with the mounting dimensions of the stainless steel straps.  The pole construction must be capable of supporting up to 8 times the total load of the dome and its accessories. Step1: Assemble the pole mount adapter Use a screwdriver to loosen the three stainless steel straps and then insert them through the rectangle holes on the pole adapter.
  • Page 26 4 Inch Speed Dome Installation Manual V2.0.0 Step3: Install wall mount assembly Screw four hex screws with the spring washers to the pole adapter through the wall mount and gasket. Step4: Install dome to the mount Feed the cables through the opening on top of the back box, and attach the dome to the mount, and finally use M3 screws to secure the dome.
  • Page 27: Chapter 6 Pendant Mounting Applications

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 6 Pendant Mounting Applications 6.1 Mounting Components         Mounting Base Applicable to pendant domes with the use of the pendant pole and pole adapter.  Pendant Pole  Pendant Adapter...
  • Page 28: Pendant Mounting Instructions

    4 Inch Speed Dome Installation Manual V2.0.0 6.2 Pendant Mounting Instructions   The pendant mounting is applicable to the indoor/outdoor solid ceiling construction which should comply with the following mounting requirements:  The ceiling must be thick enough to mount the expansion screws. ...
  • Page 29 4 Inch Speed Dome Installation Manual V2.0.0 Step2: Install the pendant pole Swivel the pendant adapter into the matching pendant pole and then use the retainer screws to secure the two parts. Pull out the cables through the pendant pole and screw the pendant pole into the mounting base and use the set screws to secure the two parts as well. For outdoor applications, please apply the water-proof thread compound to the threads.
  • Page 30: Chapter 7 In-Ceiling Mounting Applications

    4 Inch Speed Dome Installation Manual V2.0.0 Chapter 7 In-ceiling Mounting Applications 7.1 Installation Conditions The in-ceiling mounting is applicable to the indoor ceiling construction which should comply with the following mounting requirements:  The height above the ceiling must be more than 250mm. ...
  • Page 31 4 Inch Speed Dome Installation Manual V2.0.0 Step2: Install the dome to the mounting hole and then tighten the key locks to secure the dome. Finally, attach the trim ring to the dome.
  • Page 32 4 Inch Speed Dome Installation Manual V2.0.0 Step3: Connect cables Connect all wiring to corresponding sockets located on the circuit board. Please refer to Section 1.2 for specific instructions.
  • Page 33: Appendix 1 Rs485 Bus Connection

    4 Inch Speed Dome Installation Manual V2.0.0 Appendix 1 RS485 Bus Connection   1. General Property of RS485 Bus According to RS485 industry bus standard, RS485 is a half-duplex communication bus which has 120Ω characteristic impendence, the maximum load ability is 32 payloads (including controller device and controlled device). 2.
  • Page 34 4 Inch Speed Dome Installation Manual V2.0.0 Figure 3 4. Problems in the Practical Application Normally, users adopt star-shape connection method in construction, under this situation, the terminal resistors must be connected between two farthest devices (as Figure 4, 1# and 15#), but this connection method is not satisfy the requirement of the RS485 industry standard so that it will lead to some problems such as signal reflection, anti-jamming ability decline when the devices are faraway.
  • Page 35 4 Inch Speed Dome Installation Manual V2.0.0 Figure 5 1. FAQ of RS485 Bus...
  • Page 36: Appendix 2 24Vac Wire Gauge & Transmission Distance

    4 Inch Speed Dome Installation Manual V2.0.0 Appendix 2 24VAC Wire Gauge & Transmission Distance The following table has described the recommended max. distance adopted for the certain wire gauge when the 24VAC voltage loss rate is less than 10%. For the AC driven device, the maximum voltage loss rate allowable is 10%. For example, for a device with the rating power of 80VA which is installed at a distance of 35 feet (10m) away from the transformer, then the minimum wire gauge required is 0.8000mm.
  • Page 37: Appendix 3 Table Of Wire Gauge Standards

    4 Inch Speed Dome Installation Manual V2.0.0 Appendix 3 Table of Wire Gauge Standards Cross-sectional Area Bare Wire Gauge Americ an Wire Gage (British)St andard Wire Gauge Bare Wire (mm)