Emergency Stop Switch Replacement - Matrix T5X-04 Service Manual

Delta mcb
Table of Contents

Advertisement

CHAPTER 9: PART REPLACEMENT GUIDE

9.16 EMERGENCY STOP SWITCH REPLACEMENT

1) Turn off power and disconnect the cord from the machine.
2) Remove the console as outlined in Section 9.12.
3) Use a Phillips screwdriver to remove two screws, one from each side of the red button (Figure A).
4) Lift the button from bracket by pulling one side out at a time (Figure B).
FIGURE A
FIGURE B
5) Use a Phillips screwdriver to remove two screws, one from each side of the mounting bracket (Figure C).
FIGURE C
6) Turn the bracket and use a straight screwdriver or pliers to compress each end of the switch and release it from the bracket (Figures D & E).
FIGURE D
FIGURE E
7) Reverse Steps 1-6 to install a new emergency stop switch. NOTE: Make sure the new switch has the same orientation as the old one
when installing, and that the wires are properly connected.
51