Emergency Stop Switch Replacement - Matrix T5X-02 Service Manual

Table of Contents

Advertisement

CHaPTer 9: ParT rePlaCemeNT GUide

9.17 emerGeNCy SToP SWiTCH rePlaCemeNT

1) Unplug treadmill.
2) Use a Phillips screwdriver to remove two screws, one from each side of the red button (figure a).
3) lift button from bracket by pulling one side our at a time (figure b).
4) Use a Phillips screwdriver to remove two screws, one from each side of the mounting bracket (figure C).
5) Turn bracket and use a straight screwdriver or pliers to compress each end of the switch and release it from the bracket (figures d & e).
6) make sure new switch has the same orientation as the old one when installing, and wires are properly connected.
fiGUre a
fiGUre b
fiGUre e
fiGUre C
fiGUre d