Reliohtino
the Enoine in Flioht
The normal relighting
ceiling
is 20000 feet, but,
relighting
may be
att~ted
throughout the altitude
envelope.
Proceed as outlined
below :
-Booster
pumps
ON
-Wait
until
Ng falls
below 5 % then carry out starting
procedure.
-GOV (red and amber) warning lights
OUT
-Starting
selector
ON
.Check that NG increases.
.
.Check that t4 remains below its limit.
.Check that the engine oil pressure increases.
.Check
that
the
following
Warning Caution
Advisory
Panel light
-go
out:
-P.MOT (ENG.P) should be out at 70 % Ng.
-Lower
the switch guard on the starter
switch.
-Check:
Warning Caution Advisory Panel GEN light
off.
-Booster
pump selected
OFF
.PUMP and FUEL P captions
Extinguished
~
: If
the starting
cycle has to be aborted, return the start
switch to the closed position
and switch off
the fuel pump.
4 ENGINE FIRE
4.1
Fire durino Enoine Start
-Close
the fuel shut-off
cock and apply the rotor brake if necessary.
-Switch
off the booster pump.
-Crank the engine for 10 seconds then switch off the battery.
-Use the nearby extinguishers
to fight
the fire.
.
4.2
Fire in Fliaht ("FIRE" light
on)
-Enter
autorotation
(see paragraph 2.1).
-Close
the fuel shut-off
cock to shut down the engine.
-Switch
off the generator and alternator
(if
installed).
-Switch
off the electrical
master "ALL OFF" switch if there is a smell
of burning.
.
DGAC Approved:
350 B3
3. 1
I A I B I C I F I
97-40
Page 3