Eurocopter AS 350 83 Flight Manual page 327

Table of Contents

Advertisement

COMPLEMENTARY FLIGHT
MANUAL'
AIR EOUIPEMENT HOIST fitted
with an end-of-travel
microswitch monitoring
system:
.
Complete the check with the following:
-Switch
on the electric
hoist.
-Unwind
the cable by approximately
one to two metres.
-Wind the cable:
As the cable winds up, check that:
the GREEN light
is LIT,
the RED light
is EXTINGUISHED.
-On completion of the hoisting
operation,
maintain the "UP" order using
the hoist operator's
grip.
During the "UP" order,
check that:
.
the GREEN light
is EXTINGUISHED,
the RED light
is EXTINGUISHED.
-Maintain
the "up" order on the hoist operator's
grip and press the test
push-button:
During the "up" order,
check that:
the GREEN light
is EXTINGUISHED,
the RED light
ILLUMINATES.
-Check to be oerformed everv 25 hoistina
ooerations :
.Free
rotation
of the hook.
.Condition
of the cable.
.Operation
of the cable extraction
mechanism.
-Ooerations
to be oerformed everv 50 hoistina
ooerations :
.Grease the hoist brake assembly.
.Clean
then grease the cable winding screw.
.
.
350 83
8.4
97-40
Page 8